COMPLETE MASS-SPECTROMETRY MASS-SPECTROMETRY DATA FIELD ACQUISITION ON THE CHROMATOGRAPHIC TIME SCALE BY TIME-RESOLVED ION MOMENTUM SPECTROMETRY WITH TIME-ARRAY DETECTION

被引:3
作者
ECKENRODE, BA
WATSON, JT
ENKE, CG
HOLLAND, JF
机构
[1] MICHIGAN STATE UNIV, DEPT CHEM, E LANSING, MI 48824 USA
[2] MICHIGAN STATE UNIV, DEPT BIOCHEM, E LANSING, MI 48824 USA
关键词
D O I
10.1021/ac00213a003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Time-resolved ion momentum spectrometry (TRIMS) is combined with time-array detection (TAD) to provide the capability for rapid acquisition of complete mass spectrometry/ mass spectrometry (MS/MS) data fields. Observation of all arrival times for all values of the magnetic field strength produces a two-dimensional field from which all MS/MS scans can be obtained. The complete fragmentation map can now be obtained for each component in a mixture, separated by chromatography. Evaluation of the TRIMS-TAD Instrument with regard to data quality, integrity, and speed is performed under raw data acquisition and real-time data reduction conditions. A 5-s acquisition of the MS/MS data field for caffeine present in an aspirin tablet demonstrates the gas chromatography (GC)-MS/MS capability of TRIMS-TAD. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:1362 / 1367
页数:6
相关论文
共 33 条
  • [1] DESIGN AND PERFORMANCE OF A MASS ANALYZED ION KINETIC-ENERGY (MIKE) SPECTROMETER
    BEYNON, JH
    COOKS, RG
    AMY, JW
    BAITINGE.WE
    RIDLEY, TY
    [J]. ANALYTICAL CHEMISTRY, 1973, 45 (12) : 1023 - +
  • [2] COLLISION-INDUCED DISSOCIATION WITH FOURIER-TRANSFORM MASS-SPECTROMETRY
    CODY, RB
    BURNIER, RC
    FREISER, BS
    [J]. ANALYTICAL CHEMISTRY, 1982, 54 (01) : 96 - 101
  • [3] FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY
    COMISAROW, MB
    MARSHALL, AG
    [J]. CHEMICAL PHYSICS LETTERS, 1974, 25 (02) : 282 - 283
  • [4] Cooks R. G., 1973, METASTABLE IONS
  • [5] COOKS RG, 1981, CHEM ENG NEWS 1130, P40
  • [6] Coutant J. E., 1972, International Journal of Mass Spectrometry and Ion Physics, Vvol8, P323, DOI 10.1016/0020-7381(72)83021-3
  • [7] POST-SECTOR BEAM DEFLECTION IN TIME-RESOLVED ION MOMENTUM SPECTROMETRY (TRIMS)
    ECKENRODE, BA
    WATSON, JT
    ENKE, CG
    HOLLAND, JF
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1988, 83 (1-2): : 177 - 187
  • [8] FLASH ADC TIME-OF-FLIGHT SPECTROMETER
    EGAN, PO
    WOODLE, K
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1982, 53 (08) : 1267 - 1269
  • [9] ENKE CG, 1987, ANAL CHEM, V59, pA1363
  • [10] ENKE CG, Patent No. 4490806