FOULING-RESISTANT, POLYMER-MODIFIED GRAPHITE-ELECTRODES

被引:21
作者
WHEELER, SK
COURY, LA
HEINEMAN, WR
机构
[1] UNIV CINCINNATI,BIOMED CHEM RES CTR,EDISON SENSOR TECHNOL CTR,CINCINNATI,OH 45221
[2] UNIV CINCINNATI,DEPT CHEM,CINCINNATI,OH 45221
基金
美国国家科学基金会;
关键词
Graphite electrodes; Methoxyphenols; Phenols;
D O I
10.1016/S0003-2670(00)83911-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Oxidation of several biochemically important phenols (phenol and tyrosine) and methoxyphenols (homovanillic acid, eugenol, vanillin and p-methoxyphenol) at spectroscopic graphite electrodes results in deactivation or fouling of the electrode surface. As has been previously well described, fouling is often due to the build-up of the oxidation products of these compounds at the electrode surface. Electrodes coated with gamma-irradiated immobilized films of poly(N-vinylpyrrolidone) do not exhibit the decrease in response with time observed at bare electrodes during the oxidation of these compounds. In some instances, this may be due to the structure of the polymer which may prevent large amounts of oxidation products from forming. In other instances, however, the nature of the products formed may differ at the coated electrodes. In this situation, responses as high as those initially obtained at bare electrodes may be obtained without the decrease in response as a function of time associated with bare electrodes. © 1990.
引用
收藏
页码:141 / 148
页数:8
相关论文
共 27 条
[1]   PROBING BRAIN CHEMISTRY WITH ELECTROANALYTICAL TECHNIQUES [J].
ADAMS, RN .
ANALYTICAL CHEMISTRY, 1976, 48 (14) :1126-&
[2]  
Bard A. J., 2001, ELECTROCHEMICAL METH, V2nd, P50
[3]   ELECTROCHEMISTRY OF NEUROPEPTIDES - A POSSIBLE METHOD FOR ASSAY AND INVIVO DETECTION [J].
BENNETT, GW ;
BRAZELL, MP ;
MARSDEN, CA .
LIFE SCIENCES, 1981, 29 (10) :1001-1007
[4]   CHARACTERIZATION AND SELECTIVITY OF ELECTRODES COATED WITH GAMMA-RADIATION-IMMOBILIZED HYDROGEL MATRICES [J].
BIRCH, ME ;
COURY, LA ;
HEINEMAN, WR .
ANALYTICAL CHEMISTRY, 1990, 62 (11) :1123-1130
[5]   GAMMA-IRRADIATED POLYMER-MODIFIED GRAPHITE-ELECTRODES WITH ENHANCED RESPONSE TO CATECHOL [J].
COURY, LA ;
BIRCH, EM ;
HEINEMAN, WR .
ANALYTICAL CHEMISTRY, 1988, 60 (06) :553-560
[6]   PULSE VOLTAMMETRY WITH MICROVOLTAMMETRIC ELECTRODES [J].
EWING, AG ;
DAYTON, MA ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1981, 53 (12) :1842-1847
[7]   SEPARATION AND DETECTION OF CLOSELY RELATED ENDORPHINS BY LIQUID-CHROMATOGRAPHY ELECTROCHEMISTRY [J].
FLEMING, LH ;
REYNOLDS, NC .
JOURNAL OF CHROMATOGRAPHY, 1986, 375 (01) :65-73
[8]  
FLEMING LH, 1984, J LIQ CHROMATOGR, V7, P493
[9]   STRATEGIES FOR ELECTROCHEMICAL IMMUNOASSAY [J].
HEINEMAN, WR ;
HALSALL, HB .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :1321-&
[10]   ROLE OF MONOMER IN GAMMA-IRRADIATED DIMETHYLDIALLYLAMMONIUM CHLORIDE MODIFIED ELECTRODES [J].
HUBER, EW ;
HEINEMAN, WR .
ANALYTICAL CHEMISTRY, 1988, 60 (22) :2467-2472