SEMIAUTOMATIC EXTERNAL DEFIBRILLATION AND IMPLANTED CARDIAC-PACEMAKERS - UNDERSTANDING THE INTERACTIONS DURING RESUSCITATION

被引:28
作者
MONSIEURS, KG
CONRAADS, VMA
GOETHALS, MPN
SNOECK, JP
BOSSAERT, LL
机构
[1] Department of Intensive Care, University Hospital Antwerp-UIA, 2650 Edegem
[2] Department of Cardiology, University Hospital Antwerp-UIA, 2650 Edegem
关键词
CARDIAC ARREST; PACEMAKER; RESUSCITATION; SEMIAUTOMATIC DEFIBRILLATION; VENTRICULAR FIBRILLATION;
D O I
10.1016/0300-9572(95)00879-X
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Many emergency medical service (EMS) systems are currently implementing semi-automatic external defibrillation (AED) by emergency medical technicians. Surprisingly little information is available on the possible interactions between AEDs and implanted cardiac pacemakers. Therefore, at present there are no clear guidelines for the use of AEDs on patients having a cardiac pacemaker. During resuscitation, multiple interactions between pacemakers and AEDs are possible. External defibrillation can cause damage to several functions of the pacemaker, On the other hand, the presence of pacemaker spikes during cardiac arrest might prohibit recognition of the ventricular fibrillation by the AED. We report on two resuscitation attempts in which the interaction between the ventricular fibrillation, an implanted dual chamber pacemaker and the AED was decisive for the defibrillation success. A clear understanding of these possible interactions is necessary for the further refining of diagnostic algorithms and clinical strategies of prehospital defibrillation.
引用
收藏
页码:127 / 131
页数:5
相关论文
共 17 条
[1]  
Operating Instructions Heartstart 3000, (1990)
[2]  
Operations Manual model 90510 First Medic 510 Semi-automatic Defibrillator, pp. 1-3, (1992)
[3]  
Zullo, Function of ventricular pacemakers during resuscitation, PACE, 13, pp. 736-744, (1990)
[4]  
Singer, Guarnieri, Kupersmith, Implanted automatic defibrillators: Effect of drugs and pacemakers, PACE, 11, pp. 2250-2262, (1988)
[5]  
Levine, Barold, Fletcher, Et al., Adverse acute and chronic effects of electrical defibrillation and cardioversion on implanted unipolar cardiac pacing systems, Journal of the American College of Cardiology, 6, pp. 1413-1422, (1983)
[6]  
Palac, Hwang, Klondnycky, Et al., Delayed pulse generator malfunction after D.C. countershock, PACE, 4, pp. 163-188, (1981)
[7]  
Aylward, Blood, Tonkin, Complications of defibrillation with permanent pacemaker in situ, PACE, 2, pp. 462-464, (1979)
[8]  
Das, Eaton, Pacemaker malfunction following transthoracic countershock, Pacing and Clinical Electrophysiology, 4, pp. 187-190, (1981)
[9]  
Calkins, Brinker, Veltri, Et al., Clinical interactions between pacemakers and automatic implantable cardioverter-defibrillators, J Am Coll Cardiol, 16, pp. 666-673, (1990)
[10]  
Slepian, Levine, Watkins, Brinker, Guarnieri, Automatic implantable cardioverter defibrillator/ permanent pacemaker interaction: Loss of pacemaker capture following AICD discharge, PACE, 10, pp. 1194-1197, (1987)