LIQUID-CHROMATOGRAPHIC DETERMINATION OF CAROTENOIDS USING DUAL-BEAM CONTINUOUS-WAVE LASER THERMAL LENS DETECTION

被引:9
作者
CHARTIER, A [1 ]
GEORGES, J [1 ]
机构
[1] LAB SCI ANALYT, F-69622 VILLEURBANNE, FRANCE
关键词
LIQUID CHROMATOGRAPHY; CAROTENOIDS; THERMAL LENS DETECTION;
D O I
10.1016/0003-2670(93)85315-B
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chromatographic separations of carotenoids were carried out with a conventional column (4.6 mm i.d.) with an analytical flow cell (10 mm path length) and a microbore column (1.0 mm i.d.) with a microcell (3 mm path length) using dual-beam thermal lens detection. The technique was compared with conventional UV-visible spectrophotometry under static conditions and with both chromatographic systems. The comparison was made in terms of signal-to-noise ratios and detection limits. The linear absorbance range was from 10(-3) to 10(-5) and from 10(-2) to 10(-4) with the analytical cell and the microcell, respectively. For three carotenoids, the minimum observable absorbance at the top of the peak was 2.4 x 10(-5) and 1.1 X 10(-4) in conventional and microbore chromatography, respectively.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 22 条
[1]   USE OF LASER DETECTORS IN CAPILLARY LIQUID-CHROMATOGRAPHY [J].
BELENKII, BG .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 434 (02) :337-361
[2]  
BERTHOD A, 1990, SPECTROCHIM ACTA REV, V13, P11
[3]   BEAM GEOMETRY OPTIMIZATION IN DUAL-BEAM THERMAL LENSING SPECTROMETRY [J].
BERTHOUD, T ;
DELORME, N ;
MAUCHIEN, P .
ANALYTICAL CHEMISTRY, 1985, 57 (07) :1216-1219
[4]  
BUFFETT CE, 1983, ANAL CHEM, V55, P376, DOI 10.1021/ac00253a045
[5]   THERMAL LENS DETECTION FOR LIQUID-CHROMATOGRAPHY [J].
BUFFETT, CE ;
MORRIS, MD .
ANALYTICAL CHEMISTRY, 1982, 54 (11) :1824-1825
[6]   SEPARATION OF CAROTENOIDS IN FRUITS AND VEGETABLES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BUSHWAY, RJ .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1985, 8 (08) :1527-1547
[7]   THERMAL LENS ABSORPTION-MEASUREMENTS ON SMALL VOLUME SAMPLES [J].
CARTER, CA ;
HARRIS, JM .
ANALYTICAL CHEMISTRY, 1984, 56 (06) :922-925
[8]   EVALUATION OF THERMAL LENS DETECTION IN FLOW-INJECTION WITH HIGH BACKGROUND ABSORBENCY [J].
CHARTIER, A ;
FOX, CG ;
GEORGES, J .
ANALYST, 1993, 118 (02) :157-160
[9]   EVALUATION OF REVERSED-PHASE LIQUID-CHROMATOGRAPHIC COLUMNS FOR RECOVERY AND SELECTIVITY OF SELECTED CAROTENOIDS [J].
EPLER, KS ;
SANDER, LC ;
ZIEGLER, RG ;
WISE, SA ;
CRAFT, NE .
JOURNAL OF CHROMATOGRAPHY, 1992, 595 (1-2) :89-101
[10]  
FURR HC, 1992, MODERN CHROMATOGRAPH, V60, P47