IMPROVED GUIDES TO TRICUSPID-VALVE REPAIR - TWO-DIMENSIONAL ECHOCARDIOGRAPHIC ANALYSIS OF TRICUSPID ANULUS FUNCTION AND COLOR FLOW IMAGING OF SEVERITY OF TRICUSPID REGURGITATION

被引:5
作者
CHILD, JS
机构
关键词
D O I
10.1016/0735-1097(89)90427-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:1275 / 1277
页数:3
相关论文
共 10 条
[1]   COMPUTER-ANALYSIS OF DOPPLER COLOR FLOW MAPPING IMAGES FOR QUANTITATIVE ASSESSMENT OF INVITRO FLUID JETS [J].
BOLGER, AF ;
EIGLER, NL ;
PFAFF, JM ;
RESSER, KJ ;
MAURER, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (02) :450-457
[2]   CAN TWO-DIMENSIONAL ECHOCARDIOGRAPHY AND DOPPLER COLOR FLOW MAPPING IDENTIFY THE NEED FOR TRICUSPID-VALVE REPAIR [J].
CHOPRA, HK ;
NANDA, NC ;
FAN, P ;
KAPUR, KK ;
GOYAL, R ;
DARUWALLA, D ;
PACIFICO, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (05) :1266-1274
[3]   CLINICAL-SIGNIFICANCE OF INVITRO AND INVIVO EXPERIMENTAL FINDINGS REGARDING DOPPLER FLOW VELOCITY RECORDINGS [J].
DEMARIA, AN ;
SMITH, MD ;
HARRISON, MR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (07) :1682-1685
[4]  
GOLDMAN ME, 1987, J THORAC CARDIOV SUR, V94, P542
[5]   COLOR DOPPLER ASSESSMENT OF MITRAL REGURGITATION WITH ORTHOGONAL PLANES [J].
HELMCKE, F ;
NANDA, NC ;
HSIUNG, MC ;
SOTO, B ;
ADEY, CK ;
GOYAL, RG ;
GATEWOOD, RP .
CIRCULATION, 1987, 75 (01) :175-183
[6]   FACTORS INFLUENCING THE STRUCTURE AND SHAPE OF STENOTIC AND REGURGITANT JETS - AN INVITRO INVESTIGATION USING DOPPLER COLOR FLOW MAPPING AND OPTICAL-FLOW VISUALIZATION [J].
KRABILL, KA ;
SUNG, HW ;
TAMURA, T ;
CHUNG, KJ ;
YOGANATHAN, AP ;
SAHN, DJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (07) :1672-1681
[7]   SEMIQUANTITATIVE GRADING OF SEVERITY OF MITRAL REGURGITATION BY REAL-TIME TWO-DIMENSIONAL DOPPLER FLOW IMAGING TECHNIQUE [J].
MIYATAKE, K ;
IZUMI, S ;
OKAMOTO, M ;
KINOSHITA, N ;
ASONUMA, H ;
NAKAGAWA, H ;
YAMAMOTO, K ;
TAKAMIYA, M ;
SAKAKIBARA, H ;
NIMURA, Y .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (01) :82-88
[8]   QUANTITATIVE ASSESSMENT OF MITRAL REGURGITATION BY DOPPLER COLOR FLOW IMAGING - ANGIOGRAPHIC AND HEMODYNAMIC CORRELATIONS [J].
SPAIN, MG ;
SMITH, MD ;
GRAYBURN, PA ;
HARLAMERT, EA ;
DEMARIA, AN ;
OBRIEN, M ;
KWAN, OL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (03) :585-590
[9]   DETECTION AND EVALUATION OF TRICUSPID REGURGITATION USING A REAL-TIME, TWO-DIMENSIONAL, COLOR-CODED, DOPPLER FLOW IMAGING-SYSTEM - COMPARISON WITH CONTRAST TWO-DIMENSIONAL ECHOCARDIOGRAPHY AND RIGHT VENTRICULOGRAPHY [J].
SUZUKI, Y ;
KAMBARA, H ;
KADOTA, K ;
TAMAKI, S ;
YAMAZATO, A ;
NOHARA, R ;
OSAKADA, G ;
KAWAI, C ;
KUBO, S ;
KARAGUCHI, T .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (10) :811-815
[10]   THE TRICUSPID-VALVE ANNULUS - STUDY OF SIZE AND MOTION IN NORMAL SUBJECTS AND IN PATIENTS WITH TRICUSPID REGURGITATION [J].
TEI, C ;
PILGRIM, JP ;
SHAH, PM ;
ORMISTON, JA ;
WONG, M .
CIRCULATION, 1982, 66 (03) :665-671