ASSESSMENT OF INTRACARDIAC SHUNTS WITH GADOLINIUM-ENHANCED ULTRAFAST MR IMAGING

被引:16
作者
MANNING, WJ
ATKINSON, DJ
PARKER, JA
EDELMAN, RR
机构
[1] HARVARD UNIV,BETH ISRAEL HOSP,DEPT MED,DIV CARDIOVASC,THORNDIKE LAB,BOSTON,MA 02215
[2] HARVARD UNIV,SCH MED,DEPT RADIOL,BOSTON,MA 02115
关键词
ATRIAL SEPTAL DEFECT; GADOLINIUM; HEART; MR; MAGNETIC RESONANCE (MR); CONTRAST ENHANCEMENT; VENTRICULAR SEPTAL DEFECT;
D O I
10.1148/radiology.184.2.1620828
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dye dilutional techniques are widely accepted for the assessment of intracardiac shunts, but current techniques require arterial access or radioisotope injection. Ultrafast (< 500 msec) magnetic resonance (MR) imaging is ideally suited for the evaluation of an indicator during passage through the heart. Twenty patients were studied, including 13 with shunts. Four-chamber, T1-weighted images were obtained during bolus injection of gadopentetate dimeglumine. A single image was obtained in 420 msec, with repetitive images acquired after each QRS complex. After the contrast material was injected, there was pronounced signal intensity enhancement in the right atrium, followed by the right ventricular cavity, left atrium, left ventricular cavity, and descending aorta. Patients with substantial intracardiac shunts demonstrated early recirculation. First-pass contrast material-enhanced MR imaging is a promising new technique for the rapid assessment of intracardiac shunts. Combined with anatomic and functional MR imaging techniques, it can help provide a comprehensive noninvasive evaluation of suspected intracardiac shunts or provide follow-up in patients with known shunts.
引用
收藏
页码:357 / 361
页数:5
相关论文
共 16 条
[1]   1ST-PASS CARDIAC PERFUSION - EVALUATION WITH ULTRAFAST MR IMAGING [J].
ATKINSON, DJ ;
BURSTEIN, D ;
EDELMAN, RR .
RADIOLOGY, 1990, 174 (03) :757-762
[2]   ATRIAL-LEVEL SHUNTS - SENSITIVITY AND SPECIFICITY OF MR IN DIAGNOSIS [J].
DIETHELM, L ;
DERY, R ;
LIPTON, MJ ;
HIGGINS, CB .
RADIOLOGY, 1987, 162 (01) :181-186
[3]   0.3-SECOND FLASH MRI OF THE HUMAN-HEART [J].
FRAHM, J ;
MERBOLDT, KD ;
BRUHN, H ;
GYNGELL, ML ;
HANICKE, W ;
CHIEN, D .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :150-157
[4]   QUANTITATION OF INTRACARDIAC SHUNTS BY CINE-CT [J].
GARRETT, JS ;
JASCHKE, W ;
AHERNE, T ;
BOTVINICK, EH ;
HIGGINS, CB ;
LIPTON, MJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (01) :82-87
[5]  
GROSCH W, 1986, CHEM PHYSICS BAKING, P155
[6]   MR OF THE HEART - ANATOMY, PHYSIOLOGY, AND METABOLISM [J].
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (02) :239-248
[7]  
HOLLMAN BL, 1988, HEART DISEASE TXB CA, P315
[8]   RADIONUCLIDE ANGIOCARDIOGRAPHY IN THE DIAGNOSIS OF CONGENITAL HEART DISORDERS [J].
JONES, RH ;
AUSTIN, EH ;
PETER, CA ;
SABISTON, DC .
ANNALS OF SURGERY, 1981, 193 (06) :710-718
[9]   QUANTITATION OF SHUNTING AT THE ATRIAL LEVEL USING RAPID ACQUISITION COMPUTED-TOMOGRAPHY WITH COMPARISON WITH CARDIAC-CATHETERIZATION [J].
MACMILLAN, RM ;
REES, MR ;
ELDREDGE, WJ ;
MARANHAO, V ;
CLARK, DL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (04) :946-948
[10]   CORRELATION BETWEEN MAGNETIC-RESONANCE-IMAGING OF THE HEART AND CARDIAC ANATOMY [J].
NAZARIAN, GK ;
JULSRUD, PR ;
EHMAN, RL ;
EDWARDS, WD .
MAYO CLINIC PROCEEDINGS, 1987, 62 (07) :573-583