SUPERRESOLUTION IN CONFOCAL SCANNING MICROSCOPY - GENERALIZED INVERSION FORMULAS

被引:10
作者
DEFRISE, M [1 ]
DEMOL, C [1 ]
机构
[1] UNIV LIBRE BRUXELLES,DEPT MATH,B-1050 BRUSSELS,BELGIUM
关键词
D O I
10.1088/0266-5611/8/2/001
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
It was shown in previous papers that the resolution of a confocal scanning microscope can be significantly improved by measuring, for each scanning position, the full diffraction image and by inverting these data to recover the value of the object at the confocal point. In the present paper, we generalize the data inversion procedure by allowing, for reconstructing the object at a given point, to make use of the data samples recorded at other scanning positions. This leads us to a family of generalized inversion formulae, either exact or approximate. Some previously known formulae are re-derived here as special cases in a particularly simple way.
引用
收藏
页码:175 / 185
页数:11
相关论文
共 13 条
[1]   ANALYTIC INVERSION-FORMULA FOR CONFOCAL SCANNING MICROSCOPY [J].
BERTERO, B ;
DEMOL, C ;
PIKE, ER .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (09) :1748-1750
[2]   SUPER-RESOLUTION IN CONFOCAL SCANNING MICROSCOPY .2. THE INCOHERENT CASE [J].
BERTERO, M ;
BOCCACCI, P ;
DEFRISE, M ;
DEMOL, C ;
PIKE, ER .
INVERSE PROBLEMS, 1989, 5 (04) :441-461
[3]   SUPERRESOLUTION IN CONFOCAL SCANNING MICROSCOPY .4. THEORY OF DATA INVERSION BY THE USE OF OPTICAL MASKS [J].
BERTERO, M ;
BOCCACCI, P ;
DAVIES, RE ;
MALFANTI, F ;
PIKE, ER ;
WALKER, JG .
INVERSE PROBLEMS, 1992, 8 (01) :1-23
[4]   SUPERRESOLUTION IN CONFOCAL SCANNING MICROSCOPY [J].
BERTERO, M ;
BRIANZI, P ;
PIKE, ER .
INVERSE PROBLEMS, 1987, 3 (02) :195-212
[5]   SUPERRESOLUTION IN CONFOCAL SCANNING MICROSCOPY .3. THE CASE OF CIRCULAR PUPILS [J].
BERTERO, M ;
BOCCACCI, P ;
DAVIES, RE ;
PIKE, ER .
INVERSE PROBLEMS, 1991, 7 (05) :655-674
[6]   RESOLUTION IN DIFFRACTION-LIMITED IMAGING, A SINGULAR VALUE ANALYSIS .4. THE CASE OF UNCERTAIN LOCALIZATION OR NON-UNIFORM ILLUMINATION OF THE OBJECT [J].
BERTERO, M ;
DEMOL, C ;
PIKE, ER ;
WALKER, JG .
OPTICA ACTA, 1984, 31 (08) :923-946
[7]   CONFOCAL SCANNING LIGHT-MICROSCOPY WITH HIGH APERTURE IMMERSION LENSES [J].
BRAKENHOFF, GJ ;
BLOM, P ;
BARENDS, P .
JOURNAL OF MICROSCOPY-OXFORD, 1979, 117 (NOV) :219-232
[8]   SIGNAL RESTORATION FOR LINEAR-SYSTEMS WITH WEIGHTED INPUTS - SINGULAR VALUE ANALYSIS FOR 2 CASES OF LOW-PASS FILTERING [J].
GORI, F ;
GUATTARI, G .
INVERSE PROBLEMS, 1985, 1 (01) :67-85
[9]   IMAGE-FORMATION IN SCANNING MICROSCOPE [J].
SHEPPARD, CJR ;
CHOUDHURY, A .
OPTICA ACTA, 1977, 24 (10) :1051-1073
[10]  
SHEPPARD CJR, 1988, OPTIK, V80, P53