FLOW DYNAMICS ACROSS END-TO-END VASCULAR BYPASS GRAFT ANASTOMOSES

被引:44
作者
KIM, YH
CHANDRAN, KB
BOWER, TJ
CORSON, JD
机构
[1] UNIV IOWA,COLL ENGN,DEPT BIOMED ENGN,1204 ENGN BLDG,IOWA CITY,IA 52242
[2] UNIV IOWA,DEPT SURG,IOWA CITY,IA 52242
关键词
ANASTOMOTIC NEOINTIMAL FIBROUS HYPERPLASIA; VASCULAR GRAFTS; END-TO-END ANASTOMOSES; COMPLIANCE; WALL SHEAR STRESS;
D O I
10.1007/BF02368624
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this article, a numerical simulation of steady flow across an end-to-end vascular bypass graft anastomosis is presented. In vitro experiments were performed to determine the variations in the conduit cross section at the anastomosis. Penrose surgical drainage tubing was used to simulate an artery and was anastomosed with Polytetrafluoroethylene (PTFE) vascular grafts using a continuous suturing technique. Artery to artery anastomosis was simulated by suturing two Penrose tubing segments. The anastomotic specimens were subject to static transmural pressure in the physiologic range to determine the instantaneous diameter and compliance as a function of the distance from the anastomotic site. The experimentally determined geometries were used to simulate steady flow through an end-to-end anastomosis using the finite analytic (FA) numerical solution technique. The results demonstrated a region of flow separation 2 mm distal to the Penrose tubing-Penrose tubing anastomosis (simulating an artery-artery anastomosis) at higher transmural pressures. Moreover, wall shear stresses increased proximal to the anastomosis in flow from the Penrose tubing to the graft. In flow from the graft to the Penrose tubing, low wall shear stresses were observed distal to the anastomosis. Flow separation was observed distal to the anastomosis at higher transmural pressures with uniform inlet velocity condition. The region of low shear stress in flow from PTFE graft to the Penrose tubing was located nearer to the anastomosis with thin wall grafts than that with standard wall thickness grafts. Our steady flow model studies suggest a correlation between regions of low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia in end-to-end anastomoses.
引用
收藏
页码:311 / 320
页数:10
相关论文
共 24 条
[1]  
BINNS RL, 1989, J VASC SURG, V10, P326
[2]  
BROWN CH, 1975, T AM SOC ART INT ORG, V21, P35
[3]   ATHEROMA AND ARTERIAL WALL SHEAR - OBSERVATION, CORRELATION AND PROPOSAL OF A SHEAR DEPENDENT MASS TRANSFER MECHANISM FOR ALTHEROGENESIS [J].
CARO, CG ;
FITZGERA.JM ;
SCHROTER, RC .
PROCEEDINGS OF THE ROYAL SOCIETY SERIES B-BIOLOGICAL SCIENCES, 1971, 177 (1046) :109-+
[4]   FINITE-ELEMENT ANALYSIS OF ARTERIAL ANASTOMOSES WITH VEIN, DACRON AND PTFE GRAFTS [J].
CHANDRAN, KB ;
GAO, D ;
HAN, G ;
BARANIEWSKI, H ;
CORSON, JD .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (04) :413-418
[5]   FINITE ANALYTIC NUMERICAL-METHOD FOR UNSTEADY TWO-DIMENSIONAL NAVIER STOKES EQUATIONS [J].
CHEN, CJ ;
CHEN, HC .
JOURNAL OF COMPUTATIONAL PHYSICS, 1984, 53 (02) :209-226
[6]  
CLOWES AW, 1985, AM J PATHOL, V118, P43
[7]   FLOW IN THE THORACIC AORTA [J].
FARTHING, S ;
PERONNEAU, P .
CARDIOVASCULAR RESEARCH, 1979, 13 (11) :607-620
[9]  
HASSON JE, 1984, ARCH SURG-CHICAGO, V119, P788
[10]   SUTURE TECHNIQUE AND PARA-ANASTOMOTIC COMPLIANCE [J].
HASSON, JE ;
MEGERMAN, J ;
ABBOTT, WM .
JOURNAL OF VASCULAR SURGERY, 1986, 3 (04) :591-598