EFFECT OF TEMPORARY OCCLUSION OF THE HEPATIC VEIN ON DUAL BLOOD-SUPPLY IN THE LIVER - EVALUATION WITH SPIRAL CT

被引:108
作者
MURATA, S
ITAI, Y
ASATO, M
KOBAYASHI, H
NAKAJIMA, K
EGUCHI, N
SAIDA, Y
KURAMOTO, K
TOHNO, E
机构
[1] HITACHI GEN HOSP,DEPT RADIOL,HITACHI,IBARAKI,JAPAN
[2] NIPPON MED COLL,DEPT RADIOL,TOKYO,JAPAN
关键词
HEPATIC VEINS; STENOSIS OR OBSTRUCTION; LIVER; BLOOD SUPPLY; CT;
D O I
10.1148/radiology.197.2.7480676
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the contribution of hepatic veins to the dual blood supply in the liver under temporary hepatic venous occlusion. MATERIALS AND METHODS: Selected hepatic veins in 23 patients with liver tumors were temporarily occluded with a balloon catheter. Computed tomography (CT) arteriography, CT during arterial portography (CTAP), or both were performed with a spiral technique with and without temporary occlusion of a hepatic vein. RESULTS: After hepatic vein occlusion, a web-demarcated wedge-shaped area of hypoattenuation was seen at CTAP and/or hyperattenuation was seen at CT arteriography in the following regions: left lobe (left hepatic vein), ventral part of the anterior segment and the medial segment except for the ventromedial part (middle hepatic vein), dorsal part of the anterior segment and the ventral part of the posterior segment (right hepatic vein), and dorsocaudal part of the right lobe (inferior right hepatic veins). CONCLUSION: After hepatic venous occlusion, the pori-al veins become draining veins and the occluded area is supplied with arterial blood alone.
引用
收藏
页码:351 / 356
页数:6
相关论文
共 20 条
  • [1] BANNER RL, 1958, CANCER, V11, P22, DOI 10.1002/1097-0142(195801/02)11:1<22::AID-CNCR2820110106>3.0.CO
  • [2] 2-V
  • [3] CHARNSANGAVEJ C, 1988, RADIOLOGY, V169, P405
  • [4] COLLATERAL CHANNELS AND HISTOPATHOLOGY IN HEPATIC VEIN OCCLUSION
    CHO, KJ
    GEISINGER, KR
    SHIELDS, JJ
    FORREST, ME
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (04) : 703 - 709
  • [5] CT AND SONOGRAPHIC APPEARANCE OF HEPATIC VEIN OBSTRUCTION
    HARTER, LP
    GROSS, BH
    STHILAIRE, J
    FILLY, RA
    GOLDBERG, HI
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (01) : 176 - 178
  • [6] HOWARD CH, 1989, RADIOLOGY, V170, P795
  • [7] SEGMENTAL INTENSITY DIFFERENCES IN THE LIVER ON MR IMAGES - A SIGN OF INTRAHEPATIC PORTAL FLOW STOPPAGE
    ITAI, Y
    OHTOMO, K
    KOKUBO, T
    OKADA, Y
    YAMAUCHI, T
    YOSHIDA, H
    [J]. RADIOLOGY, 1988, 167 (01) : 17 - 19
  • [8] COMPUTED TOMOGRAPHIC APPEARANCE OF RESECTABLE PANCREATIC-CARCINOMA
    ITAI, Y
    ARAKI, T
    TASAKA, A
    MARUYAMA, M
    [J]. RADIOLOGY, 1982, 143 (03) : 719 - 726
  • [9] KANAZAWA S, 1993, JVIR, V6, P759
  • [10] Kanazawa Susumu, 1992, Nippon Acta Radiologica, V52, P1408