A COMPARISON OF RESORBABLE AND METALLIC FIXATION IN HEALING OF CALVARIAL BONE-GRAFTS

被引:103
作者
EPPLEY, BL [1 ]
SADOVE, AM [1 ]
机构
[1] INDIANA UNIV,MED CTR,DIV PLAST SURG,INDIANAPOLIS,IN
关键词
D O I
10.1097/00006534-199508000-00009
中图分类号
R61 [外科手术学];
学科分类号
摘要
The effects of a resorbable fixation plate composed of a polylactic acid-polyglycolic acid copolymer were compared with those of a metallic fixation plate of similar dimensions in an animal calvarial bone-graft healing model. Bilateral parietal bone grafts in 20 mature rabbits were fixed into position with a titanium mesh plate on one side and a polymer mesh plate on the other side. After 2, 6, 9, and 12 months, cross-sectional histology was used to compare osteotomy line healing,, tissue response to the fixation material, and the amount of resorbable plate degradation. After 2 months, no changes in the dimensions of the resorbable plate were observed. The bone grafts fixed by both metal and polymer plates exhibited incomplete healing along the osteotomy lines. After 6 months, there was a 66 percent reduction in the dimensions of the resorbable plate and vertical shortening of screw length. Complete healing was seen along all osteotomy lines of both bone grafts. After 9 months, less than 1 percent of the resorbable mesh plate remained as a small film underneath a collagenous capsule. No polymer was seen within the confines of the screw holes. After 1 year, no evidence of polymer was seen either on the external cranial surface or within any of the screw holes. Bony union was observed across all osteotomy sites. The screw hole outlines persisted. The resorbable plate demonstrated fixation stability similar to that of metal with comparable osteotomy line healing. No adverse local inflammatory reactions were seen as the polymer composite progressed to complete degradation by 1 year.
引用
收藏
页码:316 / 322
页数:7
相关论文
共 18 条
[1]   FOREIGN-BODY REACTIONS TO RESORBABLE POLY(L-LACTIDE) BONE PLATES AND SCREWS USED FOR THE FIXATION OF UNSTABLE ZYGOMATIC FRACTURES [J].
BERGSMA, EJ ;
ROZEMA, FR ;
BOS, RRM ;
DEBRUIJN, WC .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (06) :666-670
[2]   DEGRADATION OF AND TISSUE REACTION TO BIODEGRADABLE POLY(L-LACTIDE) FOR USE AS INTERNAL-FIXATION OF FRACTURES - A STUDY IN RATS [J].
BOS, RRM ;
ROZEMA, FR ;
BOERING, G ;
NIJENHUIS, AJ ;
PENNINGS, AJ ;
VERWEY, AB ;
NIEUWENHUIS, P ;
JANSEN, HWB .
BIOMATERIALS, 1991, 12 (01) :32-36
[3]   RESORBABLE POLY(L-LACTIDE) PLATES AND SCREWS FOR THE FIXATION OF ZYGOMATIC FRACTURES [J].
BOS, RRM ;
BOERING, G ;
ROZEMA, FR ;
LEENSLAG, JW .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1987, 45 (09) :751-753
[4]   DEGRADATION AND TISSUE REPLACEMENT OF AN ABSORBABLE POLYGLYCOLIDE SCREW IN THE FIXATION OF RABBIT FEMORAL OSTEOTOMIES [J].
BOSTMAN, O ;
PAIVARINTA, U ;
PARTIO, E ;
VASENIUS, J ;
MANNINEN, M ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :1021-1031
[5]   FOREIGN-BODY REACTIONS TO FRACTURE FIXATION IMPLANTS OF BIODEGRADABLE SYNTHETIC-POLYMERS [J].
BOSTMAN, O ;
HIRVENSALO, E ;
MAKINEN, J ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04) :592-596
[6]   OSTEOLYTIC CHANGES ACCOMPANYING DEGRADATION OF ABSORBABLE FRACTURE FIXATION IMPLANTS [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04) :679-682
[7]   ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :148-153
[8]   A COMPARATIVE SCANNING ELECTRON-MICROSCOPIC STUDY ON DEGRADATION OF ABSORBABLE LIGATING CLIPS INVIVO AND INVITRO [J].
CHEGINI, N ;
HAY, DL ;
VONFRAUNHOFER, JA ;
MASTERSON, BJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (01) :71-79
[9]  
GERLACH KL, 1993, CLIN MATER, V13, P21, DOI 10.1016/0267-6605(93)90085-L
[10]   BIODEGRADABLE POLYMERS FOR USE IN SURGERY - POLYGLYCOLIC-POLY(ACTIC ACID) HOMOPOLYMERS AND COPOLYMERS .1. [J].
GILDING, DK ;
REED, AM .
POLYMER, 1979, 20 (12) :1459-1464