A FOURIER DOMAIN TECHNIQUE FOR IONOSPHERIC TOMOGRAPHY

被引:10
作者
NA, H [1 ]
SHEN, J [1 ]
LEE, H [1 ]
机构
[1] UNIV CALIF SANTA BARBARA,DEPT ELECT & COMP ENGN,SANTA BARBARA,CA 93106
关键词
D O I
10.1029/94RS03182
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Ionospheric tomography is an emerging technique for two-dimensional reconstruction of the electron density distribution in the ionosphere. One of the fundamental difficulties with this technique, currently, is the limited resolving capability caused by the physical constraints of the data acquisition scheme. The angles of the signal propagation paths are restricted to a certain angular coverage because each ground station can only make observations over a limited range. As a result, the corresponding projection angles of the data are severely limited. This effect creates a cone-shaped region in the spatial-frequency domain, where spectral content is not available. Because of the incomplete information content of the data, uniqueness of the solution to the inverse problem does not exist. In this paper a new Fourier domain extrapolation technique is presented which utilizes the information contained in the known region of the spectrum to estimate the frequency samples in the missing cone area. Unlike conventional two-dimensional extrapolation techniques, this method uses bidirectional extrapolation to maximize the amount of known information in each extrapolation step, By fully utilizing the information of the measured data, the resulting image provides a more accurate estimation of the electron density distribution.
引用
收藏
页码:747 / 754
页数:8
相关论文
共 16 条
[1]  
Austen J.R., Franke S.J., Liu C.H., Ionospheric imaging using computerized tomography, Radio Sci., 23, 3, pp. 299-307, (1988)
[2]  
Inouye T., Image reconstruction with limited angle projection data, IEEE Trans. Nucl. Sci., 26, 4, (1979)
[3]  
Kak A.C., Slaney M., Principles of Computerized Tomographic Imaging, (1988)
[4]  
Kim J.H., Kwak K.Y., Park S.B., Cho Z.H., Projection space iteration reconstruction‐reprojection, IEEE Transactions on Medical Imaging, 4, 9, pp. 139-144, (1985)
[5]  
Kunitsyn V.E., Tereshchenko E.D., Radio tomography of the ionosphere, IEEE Ant. Propag. Mag., 34, 10, pp. 22-32, (1992)
[6]  
Lee H., Sullivan D.P., Fundamental limitation of resolution enhancement by wave‐field extrapolation, J. Acoust. Soc. Am., 2, 84, pp. 611-617, (1988)
[7]  
Lee H., Lin Z., Huang T.S., Performance and limitation of discrete band‐limited signal extrapolation, Proc. Int. Conf. Acoust., Speech, Signal Processing, 1986, pp. 1645-1648, (1986)
[8]  
Lee H., Sullivan D.P., Huang T.S., Improvement of discrete band‐limited signal extrapolation by iterative subspace modification, Proc. Int. Conf. Acoust., Speech, Signal Processing, 1987, pp. 1569-1572, (1987)
[9]  
Na H., (1991)
[10]  
Na H., Lee H., Resolution analysis of tomographic reconstruction of electron density profiles in the ionosphere, International Journal of Imaging Systems and Technology, 2, 3, pp. 209-218, (1990)