PERCUTANEOUS INFERIOR VENA-CAVAL FILTERS - FOLLOW-UP OF 7 DESIGNS IN 320 PATIENTS

被引:255
作者
FERRIS, EJ
MCCOWAN, TC
CARVER, DK
MCFARLAND, DR
机构
[1] Department of Radiology, Arkansas Univ. for Medical Sciences, Mail Slot 556, Little Rock, AR 72205
关键词
INTERVENTIONAL PROCEDURES; COMPLICATIONS; VENAE-CAVAE; FILTERS; INTERVENTIONAL PROCEDURE;
D O I
10.1148/radiology.188.3.8351361
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three hundred twenty-four percutaneous inferior vena caval (IVC) filters of different designs were placed in 320 patients from April 1985 through June 1992. No acute mortality or substantial morbidity was attributed to filter placement. Radiologic or pathologic follow-up data were obtained in 227 (71%) patients (230 filters); clinical follow-up data only were obtained in 50 (16%) patients (50 filters). One hundred twenty (43%) patients died; post-filter-placement pulmonary emboli (PE) were related to the cause of death in eight. At IVC filter imaging studies, 26 of 137 (19%) filters demonstrated caval thrombus; 12 of 132 (9%) filters had delayed penetration through the IVC wall of greater than 3 mm; 13 of 230 (6%) filters migrated more than 1 cm; and five of 230 (2%) filters had fracture of a strut or leg. Deep venous thrombosis (DVT) at the insertion puncture site or in the lower extremity was noted in 26 of 117 (22%) cases of filter placement. Among patients without imaging studies, clinical suspicion of complications included PE in four patients, IVC thrombus in 14 patients, and lower-extremity DVT in 10 patients. Long-term clinical and radiologic follow-up of all IVC filters is indicated due to the relatively high prevalence of some complications.
引用
收藏
页码:851 / 856
页数:6
相关论文
共 48 条
[1]   SPONTANEOUS FRACTURE OF A VENA-TECH INFERIOR VENA-CAVAL FILTER [J].
AWH, MH ;
TAYLOR, FC ;
LU, CT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) :177-178
[2]   COMPLICATIONS ENCOUNTERED WITH THE USE OF THE GREENFIELD FILTER [J].
CARABASI, RA ;
MORITZ, MJ ;
JARRELL, BE .
AMERICAN JOURNAL OF SURGERY, 1987, 154 (02) :163-168
[3]   GREENFIELD FILTER - PERCUTANEOUS PLACEMENT IN 50 PATIENTS [J].
DENNY, DF ;
DORFMAN, GS ;
CRONAN, JJ ;
GREENWOOD, LH ;
MORSE, SS ;
YOSELEVITZ, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (02) :427-429
[4]   PERCUTANEOUS INFERIOR VENA-CAVAL FILTERS [J].
DORFMAN, GS .
RADIOLOGY, 1990, 174 (03) :987-992
[6]   IATROGENIC CHANGES AT THE VENOTOMY SITE AFTER PERCUTANEOUS PLACEMENT OF THE GREENFIELD FILTER [J].
DORFMAN, GS ;
CRONAN, JJ ;
PAOLELLA, LP ;
LAMBIASE, RE ;
HAAS, RA ;
SCOLA, FH ;
SCHEPPS, B .
RADIOLOGY, 1989, 173 (01) :159-162
[7]   EXPERIENCE WITH THE AMPLATZ RETRIEVABLE VENA-CAVA FILTER [J].
EPSTEIN, DH ;
DARCY, MD ;
HUNTER, DW ;
COLEMAN, CC ;
TADAVARTHY, SM ;
MURRAY, PD ;
CASTANEDAZUNIGA, WR ;
AMPLATZ, K .
RADIOLOGY, 1989, 172 (01) :105-110
[8]   RECURRENT PULMONARY-EMBOLISM AFTER GREENFIELD FILTER PLACEMENT [J].
GEISINGER, MA ;
ZELCH, MG ;
RISIUS, B .
RADIOLOGY, 1987, 165 (02) :383-384
[9]   INFERIOR VENA-CAVAL FILTERS - ANALYSIS OF 5 CURRENTLY AVAILABLE DEVICES [J].
GRASSI, CJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (04) :813-821
[10]  
GREENFIELD LJ, 1973, SURGERY, V73, P599