POLYELECTROLYTE-ENHANCED ULTRAFILTRATION OF COPPER FROM A WASTE STREAM

被引:12
作者
MUNDKUR, SD
WATTERS, JC
机构
[1] Department Of Chemical Engineering, University Of Louisville, Louisville
关键词
D O I
10.1080/01496399308018026
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The concentration of copper in a simulated wastewater was successfully reduced from 100 ppm to less than 1 ppm by polyelectrolyte-enhanced ultrafiltration. In polyelectrolyte-enhanced ultrafiltration, copper is ionically bound to the polymeric chain of an anionic polyelectrolyte. Ultrafiltration then filters out this large copper-polyelectrolyte complex. At the same polyelectrolyte-to-copper ratio in the 1:1 to 3:1 (weight basis) range and a feed temperature in the 15 to 40-degrees-C range, sodium carboxymethyl cellulose was more efficient for copper removal and exhibited higher flux values than sodium polystyrene sulfonate. The experiments showed that transmembrane pressure has a minimal effect on removal of copper whereas the polyelectrolyte-to-copper ratio has considerable influence. It was also seen that the permeate copper concentration decreased with a decrease in feed temperature. Decreasing the feed temperature also caused a reduction in flux because of an increase in the viscosity of the feed solution.
引用
收藏
页码:1157 / 1168
页数:12
相关论文
共 12 条
[1]  
Aptel P, 1986, SYNTHETIC MEMBRANES
[2]   THE ELECTROSTATIC FREE ENERGY OF POLYELECTROLYTE SOLUTIONS .2. FULLY STRETCHED MACROMOLECULES [J].
LIFSON, S ;
KATCHALSKY, A .
JOURNAL OF POLYMER SCIENCE, 1954, 13 (68) :43-55
[3]  
PADGETT DL, 1989, THESIS U LOUISVILLE
[4]  
RINAUDO M, 1972, POLYELECTROLYTES, V1, P157
[5]  
SASAKI JK, 1972, POLYELECTROLYTES, V1
[6]  
SCAMEHORN JF, 1985, SEPAR SCI TECHNOL, V20, P257
[7]  
SCAMEHORN JF, 1989, SURFACTANT BASED SEP, pCH2
[8]  
SCAMEHORN JF, 1988, CONCENTRATION POLARI
[9]  
SCOTT J, 1980, CHEM TECH REV, V147
[10]  
SILBERBERG A, 1972, POLYELECTROLYTES, V1