DUAL-ENERGY X-RAY ABSORPTIOMETRY MEASUREMENTS OF BODY-COMPOSITION - EFFECTS OF DEPTH AND TISSUE THICKNESS, INCLUDING COMPARISONS WITH DIRECT ANALYSIS

被引:72
作者
JEBB, SA
GOLDBERG, GR
JENNINGS, G
ELIA, M
机构
[1] MRC Dunn Clinical Nutrition Centre, Cambridge CB2 2DH, Hills Road
关键词
DIRECT ANALYSIS; DXA; FAT; LEAN;
D O I
10.1042/cs0880319
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
1. There are few data regarding the accuracy of Hologic QDR-1000W dual-energy X-ray absorptiometry for the measurement of body composition. In two studies, one in an in vitro experimental system using oil and water mixtures and the other in samples of pork meat, the effect of depth and tissue thickness on the measured composition was assessed. In the latter study the measured fat mass was compared with that measured by direct analysis. 2. All data indicated a trend in the measured fat mass with depth, such that more fat was measured at extremes of depth (< 10 cm and > 25 cm) than at intermediate depths. 3. In samples of meat weighing approximately 55 kg, dual X-ray absorptiometry significantly underestimated the absolute fat mass compared with direct analysis (mean 20.4 +/- 1.65%) by 5-8% or 1-4 kg of fat. 4. These findings are of direct relevance to both clinical and research work using this technique to measure body composition, in particular in circumstances in which changes in body composition and/or tissue thickness are anticipated.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 9 条
[1]   4-COMPONENT MODEL FOR THE ASSESSMENT OF BODY-COMPOSITION IN HUMANS - COMPARISON WITH ALTERNATIVE METHODS, AND EVALUATION OF THE DENSITY AND HYDRATION OF FAT-FREE MASS [J].
FULLER, NJ ;
JEBB, SA ;
LASKEY, MA ;
COWARD, WA ;
ELIA, M .
CLINICAL SCIENCE, 1992, 82 (06) :687-693
[2]  
FULLER NJ, 1992, CLIN PHYSL, V12, P1
[3]  
LASKEY MA, 1992, EUR J CLIN NUTR, V46, P39
[4]  
MAZESS RB, 1981, CALCIFIED TISSUE INT, V33, P361
[5]   DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR TOTAL-BODY AND REGIONAL BONE-MINERAL AND SOFT-TISSUE COMPOSITION [J].
MAZESS, RB ;
BARDEN, HS ;
BISEK, JP ;
HANSON, J .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 51 (06) :1106-1112
[6]  
PIERSON RN, 1993, FASEB J, V7, pA68
[7]   USE OF DUAL-ENERGY X-RAY ABSORPTIOMETRY IN BODY-COMPOSITION STUDIES - NOT YET A GOLD STANDARD [J].
ROUBENOFF, R ;
KEHAYIAS, JJ ;
DAWSONHUGHES, B ;
HEYMSFIELD, SB .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 58 (05) :589-591
[8]   ACCURACY OF MEASUREMENTS OF BODY-COMPOSITION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY INVIVO [J].
SVENDSEN, OL ;
HAARBO, J ;
HASSAGER, C ;
CHRISTIANSEN, C .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (05) :605-608
[9]  
TOTHILL P, 1993, BASIC LIFE SCI, P385