APPLICATION OF A NEW PH-SENSITIVE FLUOROPROBE (CARBOXY-SNARF-1) FOR INTRACELLULAR PH MEASUREMENT IN SMALL, ISOLATED CELLS

被引:173
作者
BUCKLER, KJ
VAUGHANJONES, RD
机构
[1] University Laboratory of Physiology, Oxford, OX1 3PT, Parks Road
来源
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY | 1990年 / 417卷 / 02期
关键词
Carotid body; Intracellular pH; SNARF-1;
D O I
10.1007/BF00370705
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We report the use of a new pH-sensitive dualemission fluoroprobe, carboxy-seminaphthorhodafluor-1 (carboxy-SNARF-1) for ratiometric recording of intracellular pH (pHi) in small isolated cells. The method is illustrated with pHi measurement in single type-1 cells (cell diameter ∼10 μm) isolated from the carotid body of the neonatal rat. Carboxy-SNARF-1 is loaded using bath application of the acetoxymethyl ester. When excited at 540 nm, the fluoroprobe gives strong, inversely related emission signals at 590 nm and 640 nm. Stable ratiometric recordings of pHi can be achieved from a single cell (pHi 8.5-6.5) for up to 50 min. Photobleaching of the probe is minimised by illuminating at relatively low light intensity (50 W xenon lamp with 0.2% transmission neutral density filter). The probe can be calibrated in situ using the nigericin technique and this is in good quantitative agreement with the independent null-point technique (extracellular weak acid/weak base application) of Eisner et al. (1989). This fluoroprobe offers certain advantages over the other commonly used probe for pHi 2′,7′-bis-(2-carboxyethyl)-5(and -6)-carboxyfluorescein (BCECF): (i) because of its two strong pH-sensitive peak emissions, SNARF displays a good signal-to-noise ratio for ratiometric recording at low light intensities; (ii) unlike BCECF, the dual emisson of SNARF requires no sequential mechanical switching of excitation filters, thus simplifying the epifluorescence set-up; (iii) because carboxy-SNARF-1 emission signals are at the yellow/red end of the visible spectrum, fluorescent drugs like amiloride, ethyl-isopropyl-amibride (EIPA), 4,4′-diisothiocyanostilbene 2,2′-disulphonic acid (DIDS) and cinnamate analogues do not interfere with the pHi recording, even when used at high concentrations. © 1990 Springer-Verlag.
引用
收藏
页码:234 / 239
页数:6
相关论文
共 18 条
  • [1] INTRACELLULAR PH MEASUREMENT USING SINGLE EXCITATION-DUAL EMISSION FLUORESCENCE RATIOS
    BASSNETT, S
    REINISCH, L
    BEEBE, DC
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (01): : C171 - C178
  • [2] BLANK PS, 1990, BIOPHYS J, V57, pA137
  • [3] INTRACELLULAR PH REGULATION IN THE RENAL PROXIMAL TUBULE OF THE SALAMANDER
    BORON, WF
    BOULPAEP, EL
    [J]. JOURNAL OF GENERAL PHYSIOLOGY, 1983, 81 (01) : 53 - 94
  • [4] PH REGULATION IN SINGLE GLOMERULAR MESANGIAL CELLS .1. ACID EXTRUSION IN ABSENCE AND PRESENCE OF HCO-3-
    BOYARSKY, G
    GANZ, MB
    STERZEL, RB
    BORON, WF
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (06): : C844 - C856
  • [5] BUCKLER KJ, 1990, J PHYSIOL-LONDON, V423, pP65
  • [6] BUCKLER KJ, 1990, J PHYSIOL-LONDON, V426, pP22
  • [7] CABANTCHIK ZI, 1978, BIOCHIM BIOPHYS ACTA, V515, P239
  • [8] A NOVEL METHOD FOR ABSOLUTE CALIBRATION OF INTRACELLULAR PH INDICATORS
    EISNER, DA
    KENNING, NA
    ONEILL, SC
    POCOCK, G
    RICHARDS, CD
    VALDEOLMILLOS, M
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1989, 413 (05): : 553 - 558
  • [9] CHANGES IN INTRACELLULAR PH AND PH REGULATING MECHANISMS IN SOMITIC CELLS OF THE EARLY CHICK-EMBRYO - A STUDY USING FLUORESCENT PH-SENSITIVE DYE
    GILLESPIE, JI
    GREENWELL, JR
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1988, 405 : 385 - 395
  • [10] GRYNKIEWICZ G, 1985, J BIOL CHEM, V260, P3440