A miniature three-electrode electrochemical flow cell with a measuring volume of 0.15-mu-l together with appropriate electronics was designed to provide simultaneous potentiometric and conductivity measurements of flowing liquids. An antimony working electrode in the cell was used for potentiometric pH monitoring. The suitability of the detector for miniaturized flow-injection analysis and microcolumn liquid chromatography and the mutual independence of both signals obtained was demonstrated. The detector is capable of detecting changes of 50 nS cm-1 in conductivity and 0.004 in pH.
引用
收藏
页码:41 / 51
页数:11
相关论文
共 23 条
[1]   POTENTIOMETRIC DETECTOR WITH A GLASS-ELECTRODE FOR THE ION-EXCHANGE CHROMATOGRAPHY OF CARBOXYLIC-ACIDS [J].
EGASHIRA, S .
JOURNAL OF CHROMATOGRAPHY, 1980, 202 (01) :37-43
[2]   AN APPROACH TO AMPHOLYTE-DISPLACEMENT CHROMATOGRAPHY [J].
EMOND, JP ;
PAGE, M .
JOURNAL OF CHROMATOGRAPHY, 1980, 200 (NOV) :57-63
[3]  
FRITZ JS, 1982, ION CHROMATOGRAPHY
[4]   A POTENTIOMETRIC DETECTOR FOR FOLLOWING PH SHIFTS IN LIQUID-CHROMATOGRAPHY [J].
GEORGES, J ;
KHALIL, M .
ANALYTICA CHIMICA ACTA, 1986, 182 :281-284
[5]   BUFFER-FOCUSING CHROMATOGRAPHY USING MULTICOMPONENT ELECTROLYTE ELUTION SYSTEMS [J].
HEARN, MTW ;
LYTTLE, DJ .
JOURNAL OF CHROMATOGRAPHY, 1981, 218 (1-3) :483-495
[6]   MICROCOLUMN CHROMATOFOCUSING .2. HIGH-RESOLUTION CHROMATOFOCUSING USING A SLURRY PACKED CAPILLARY COLUMN LOADED WITH A 10 MU-M DEAE ANION-EXCHANGER [J].
HIROSE, A ;
ISHII, D .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (06) :360-361
[7]   MICRO-COLUMN CHROMATOFOCUSING .1. USE OF A 10-MU-M DIETHYLAMINOETHYL ANION-EXCHANGER [J].
HIROSE, A ;
ISHII, D .
JOURNAL OF CHROMATOGRAPHY, 1987, 387 :416-419
[8]   EVALUATION OF CRITICAL PARAMETERS FOR MEASUREMENT OF PH BY FLOW-INJECTION ANALYSIS - DETERMINATION OF PH IN SOIL EXTRACTS [J].
HONGBO, C ;
HANSEN, EH ;
RUZICKA, J .
ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) :209-220
[9]   DEVELOPMENT OF FOCUSING BUFFER SYSTEMS FOR GENERATION OF WIDE-RANGE PH GRADIENTS DURING HIGH-PERFORMANCE CHROMATOFOCUSING [J].
HUTCHENS, TW ;
LI, CM ;
BESCH, PK .
JOURNAL OF CHROMATOGRAPHY, 1986, 359 :157-168
[10]  
Jandera P., 1985, GRADIENT ELUTION COL