摘要
A conventional x-ray image intensifier (XRII) has been modified to enable the field of view (FOV) to be varied continuously, by adjusting the potentials at the focusing electrodes. The benefit, to system resolution, from decreasing the FOV has been characterized by measuring the modulation transfer function (MTF) of the XRII coupled to a high-resolution photo-diode array (PDA), at a number of different FOVs achieved either by electronic or optical zooming. Electronic zooming of the XRII from FOV = 24 cm to FOV = 10 cm led to an increase in f0.1 (the frequency at which MTF = 0.1) from 1.41 to 3.05 mm-1, while optical zooming increased f0.1 from 1.41 mm-1 only to 1.88 mm-1. It is proposed that the advantage, with respect to resolution gain, of electronic zooming over optical zooming was realized only when the XRII limits system resolution. The MTF of the XRII coupled to a video camera, with lower resolving power than the PDA, was measured at different FOVs to show that using electronic zooming is only marginally beneficial when the optical detector and the XRII contribute equally to the resolution degradation. However, when a higher-resolution optical detector is used, electronic zooming always yields a greater gain in resolution.
引用
收藏
页码:1653 / 1660
页数:8
相关论文
共 18 条
[1]   ANALYSIS AND CORRECTION OF IMPERFECTIONS IN THE IMAGE INTENSIFIER-TV-DIGITIZER IMAGING CHAIN [J].
BOONE, JM ;
SEIBERT, JA ;
BARRETT, WA ;
BLOOD, EA .
MEDICAL PHYSICS, 1991, 18 (02) :236-242
[2]  
BOONE JM, 1990, RADIOLOGY, V177, P136
[3]  
CHAZALLET F, 1985, P SOC PHOTO-OPT INST, V549, P131, DOI 10.1117/12.948815
[4]   A PHOTODIODE ARRAY X-RAY-IMAGING SYSTEM FOR DIGITAL ANGIOGRAPHY [J].
CUNNINGHAM, IA ;
FENSTER, A .
MEDICAL PHYSICS, 1984, 11 (03) :303-310
[5]  
DRANGOVA M, 1990, P SOC PHOTO-OPT INS, V1231, P255, DOI 10.1117/12.18835
[6]   THE DIRECT EXAMINATION OF 3-DIMENSIONAL BONE ARCHITECTURE INVITRO BY COMPUTED-TOMOGRAPHY [J].
FELDKAMP, LA ;
GOLDSTEIN, SA ;
PARFITT, AM ;
JESION, G ;
KLEEREKOPER, M .
JOURNAL OF BONE AND MINERAL RESEARCH, 1989, 4 (01) :3-11
[7]  
FRANKEN A A J, 1972, Medicamundi, V17, P121
[8]   A TIME-DELAY INTEGRATION CHARGE-COUPLED DEVICE CAMERA FOR SLOT-SCANNED DIGITAL RADIOGRAPHY [J].
HOLDSWORTH, DW ;
GERSON, RK ;
FENSTER, A .
MEDICAL PHYSICS, 1990, 17 (05) :876-886
[9]   A DIGITAL-RADIOGRAPHIC TECHNIQUE FOR INVITRO TISSUE THICKNESS MEASUREMENT USING IODINE DISPLACEMENT [J].
HOLDSWORTH, DW ;
DUNMORE, PJ ;
ROACH, MR ;
FENSTER, A .
MEDICAL PHYSICS, 1992, 19 (03) :545-554
[10]  
HOLDSWORTH DW, 1990, P SOC PHOTO-OPT INS, V1231, P239, DOI 10.1117/12.18801