INVIVO SAMPLING USING LOOP MICRODIALYSIS PROBES COUPLED TO A LIQUID CHROMATOGRAPH

被引:9
作者
LINHARES, MC [1 ]
KISSINGER, PT [1 ]
机构
[1] PURDUE UNIV,DEPT CHEM,W LAFAYETTE,IN 47907
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1992年 / 578卷 / 02期
关键词
D O I
10.1016/0378-4347(92)80412-J
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microdialysis probes with longer membranes (20-100 mm) provide increased relative recovery over traditional shorter probes (1-4 mm) developed for neuroscience applications. The characterization and optimization of "straight through" or "loop type" probes for use in subcutaneous tissue are considered. Membrane area, probe size, inlet and outlet tubing dimensions, and flow-rate are examined for their effects on relative recovery, the total collection rate, and bulk flow through the membrane wall. Polyacrylonitrile and regenerated cellulose membrane fibers with different geometries were compared. Sampling probes used fibers 3-10 cm long. Inlet and outlet tubing was varied from 25 to 110-mu-m I.D. with lengths of 10 to 50 cm. Probe configurations optimized for relative recovery, flow-rate, and utility for in vivo use are presented. Utilizing microdialysis probes with large membrane surface areas results in relative concentration recovery of greater than 50% at flow-rates of greater than 5-mu-l/min. Therapeutic drug monitoring in subcutaneous tissue of awake animals is explored.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 19 条
[1]   MICRODIALYSIS - THEORY AND APPLICATION [J].
BENVENISTE, H ;
HUTTEMEIER, PC .
PROGRESS IN NEUROBIOLOGY, 1990, 35 (03) :195-215
[2]   BRAIN MICRODIALYSIS [J].
BENVENISTE, H .
JOURNAL OF NEUROCHEMISTRY, 1989, 52 (06) :1667-1679
[3]   STEADY-STATE THEORY FOR QUANTITATIVE MICRODIALYSIS OF SOLUTES AND WATER INVIVO AND INVITRO [J].
BUNGAY, PM ;
MORRISON, PF ;
DEDRICK, RL .
LIFE SCIENCES, 1990, 46 (02) :105-119
[4]  
BUNGEY PM, 1991, J NEUROCHEM, V57, P103
[5]   MICRODIALYSIS SAMPLING FOR DETERMINATION OF PLASMA-PROTEIN BINDING OF DRUGS [J].
HERRERA, AM ;
SCOTT, DO ;
LUNTE, CE .
PHARMACEUTICAL RESEARCH, 1990, 7 (10) :1077-1081
[6]   EFFECTS OF DIFFERENT SEMIPERMEABLE MEMBRANES ON INVITRO AND INVIVO PERFORMANCE OF MICRODIALYSIS PROBES [J].
HSIAO, JK ;
BALL, BA ;
MORRISON, PF ;
MEFFORD, IN ;
BUNGAY, PM .
JOURNAL OF NEUROCHEMISTRY, 1990, 54 (04) :1449-1452
[7]   CHARACTERIZATION BY MICRODIALYSIS OF INTERCELLULAR GLUCOSE LEVEL IN SUBCUTANEOUS TISSUE IN HUMANS [J].
JANSSON, PA ;
FOWELIN, J ;
SMITH, U ;
LONNROTH, P .
AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (02) :E218-E220
[8]   THE USE OF AN INTERNAL STANDARD FOR CONTROL OF THE RECOVERY IN MICRODIALYSIS [J].
LARSSON, CI .
LIFE SCIENCES, 1991, 49 (13) :PL73-PL78
[9]   SAMPLING LIVING SYSTEMS USING MICRODIALYSIS PROBES [J].
LUNTE, CE ;
SCOTT, DO ;
KISSINGER, PT .
ANALYTICAL CHEMISTRY, 1991, 63 (15) :A773-+
[10]   EFFECT OF VARYING THE IONIC CONCENTRATION OF A MICRODIALYSIS PERFUSATE ON BASAL STRIATAL DOPAMINE LEVELS IN AWAKE RATS [J].
OSBORNE, PG ;
OCONNOR, WT ;
UNGERSTEDT, U .
JOURNAL OF NEUROCHEMISTRY, 1991, 56 (02) :452-456