ASSESSMENT OF INTERRATER AND INTRARATER RELIABILITY IN THE EVALUATION OF METERED-DOSE INHALER TECHNIQUE

被引:24
作者
GRAY, SL
NANCE, AC
WILLIAMS, DM
PULLIAM, CC
机构
[1] School of Pharmacy, University of North Carolina, Chapel Hill, NC
关键词
D O I
10.1378/chest.105.3.710
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: To determine if a training session using videotaped metered dose inhaler (MDI) performances can result in high interrater and intrarater reliability of five evaluators assessing MDI technique. Design: Five evaluators (three pharmacists, two pulmonary fellows) were trained to evaluate MDI technique during a 2-h training session. The training session consisted of verbal instruction and practical experience in evaluating MDI technique using videotaped MDI performances of six nonstudy subjects. After the training session, the evaluators independently observed the same videotaped MDI demonstrations of 14 subjects on two occasions separated by a 7- to 10-day interval. Interrater and intrarater reliability was determined for individual steps by calculating percent agreement and intraclass correlation (ICC) coefficient. Results: Interrater. The interrater reliability for individual steps ranged from 29 to 86 percent (ICC coefficient = 0.13 to 0.81). Steps in which evaluators were in agreement for less than 9 of the 14 subjects were shaking the inhaler before inhalation, exhaling, continuing to inhale slowly, and adequate breath hold. Intrarater: The overall percent agreement by step ranged from 74 to 97 percent. Exhaling to functional residual volume (76 percent) and continuing to inhale slowly and deeply (74 percent) had the lowest overall agreement between the first and second observation day. The consistency of evaluating a step between the two observation days varied considerably depending on the step and evaluator. Conclusions: High interrater and intrarater reliability in MDI evaluation is difficult to obtain. Clinicians and researchers involved in MDI evaluation and education should be trained to achieve consistency. A single training session using videotaped MDI demonstrations was not adequate in achieving consistency among evaluators. To improve accuracy of research results, researchers should include at least two evaluators to assess MDI technique or take other measures to show and report reliability.
引用
收藏
页码:710 / 714
页数:5
相关论文
共 18 条
[1]   WHAT DETERMINES WHETHER AN ELDERLY PATIENT CAN USE A METERED DOSE INHALER CORRECTLY [J].
ALLEN, SC ;
PRIOR, A .
BRITISH JOURNAL OF DISEASES OF THE CHEST, 1986, 80 (01) :45-49
[2]   INHALER TECHNIQUE IN THE ELDERLY [J].
ARMITAGE, JM ;
WILLIAMS, SJ .
AGE AND AGEING, 1988, 17 (04) :275-278
[3]   USE AND MISUSE OF METERED-DOSE INHALERS BY PATIENTS WITH CHRONIC LUNG-DISEASE - A CONTROLLED, RANDOMIZED TRIAL OF 2 INSTRUCTION METHODS [J].
DEBLAQUIERE, P ;
CHRISTENSEN, DB ;
CARTER, WB ;
MARTIN, TR .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 140 (04) :910-916
[4]   EFFECT OF PHARMACIST COUNSELING ON AMBULATORY PATIENTS USE OF AEROSOLIZED BRONCHODILATORS [J].
DETULLIO, PL ;
CORSON, ME .
AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1987, 44 (08) :1802-1806
[5]   INCORRECT USE OF METERED DOSE INHALERS BY MEDICAL PERSONNEL [J].
GUIDRY, GG ;
BROWN, WD ;
STOGNER, SW ;
GEORGE, RB .
CHEST, 1992, 101 (01) :31-33
[6]   RISK-FACTORS FOR INADEQUATE USE OF PRESSURIZED AEROSOL INHALERS [J].
HORSLEY, MG ;
BAILIE, GR .
JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 1988, 13 (02) :139-143
[7]   PHYSICIAN KNOWLEDGE IN THE USE OF CANISTER NEBULIZERS [J].
KELLING, JS ;
STROHL, KP ;
SMITH, RL ;
ALTOSE, MD .
CHEST, 1983, 83 (04) :612-614
[8]  
LINDGREN S, 1987, EUR J RESPIR DIS, V70, P93
[9]   EVALUATION OF PHARMACISTS PRACTICE IN PATIENT EDUCATION WHEN DISPENSING A METERED-DOSE INHALER [J].
MICKLE, TR ;
SELF, TH ;
FARR, GE ;
BESS, DT ;
TSIU, SJ ;
CALDWELL, FL .
DICP-THE ANNALS OF PHARMACOTHERAPY, 1990, 24 (10) :927-930
[10]  
NEWMAN SP, 1981, EUR J RESPIR DIS, V62, P3