摘要
PURPOSE: To evaluate obliteration of an experimental aortic dissection with a balloon-expandable intravascular stent. MATERIALS AND METHODS: Fourteen adult dogs were divided into two groups. In group 1 (n = 6), a thoracoabdominal aortic dissection was surgically created to observe the natural course of this lesion. In group 2 (n = 8), a balloon-expandable intraluminal vascular graft was introduced via the femoral artery in a dissected aorta to try to obliterate the dissection. Angiography was performed postoperatively and again 6 weeks later before the aortae were explanted for pathologic evaluation. RESULTS: In group 1, postoperative aortography depicted evidence of aortic dissection in all animals. Autopsy revealed persisting dissection with reentry tear near the celiac axis in five animals. In group 2, placement of a stent at only entry and reentry sites resulted in partial obliteration of the dissection (n = 3). When the entire length of dissected aorta was treated, the dissection was completely obliterated (n = 4). CONCLUSION: An aortic dissection can be obliterated with a balloon-expandable stent if the entire dissected aorta is treated.
引用
收藏
页码:97 / 103
页数:7
相关论文
共 27 条
[1]  
ABLAZA SGG, 1978, J THORAC CARDIOV SUR, V76, P390
[2]   MANAGEMENT OF ACUTE AORTIC DISSECTIONS WITH A CYLINDER-TYPE BALLOON CATHETER TO CLOSE THE ENTRY [J].
AKABA, N ;
UJIIE, H ;
UMEZAWA, K ;
MIURA, K ;
YAMAMOTO, Y ;
HORIHOSHI, S ;
IJIMA, H .
JOURNAL OF VASCULAR SURGERY, 1986, 3 (06) :890-894
[3]   AORTIC DISSECTIONS AND DISSECTING ANEURYSMS [J].
ANAGNOSTOPOULOS, CE ;
PRABHAKAR, MJ ;
KITTLE, CF .
AMERICAN JOURNAL OF CARDIOLOGY, 1972, 30 (03) :263-+
[4]  
BACHET J, 1982, J THORAC CARDIOV SUR, V83, P212
[5]  
BLANTON FS, 1959, SURGERY, V45, P81
[6]  
CARPENTIER A, 1981, J THORAC CARDIOV SUR, V81, P659
[7]   ENDOVASCULAR STENT FOR USE IN AORTIC DISSECTION - AN INVITRO EXPERIMENT [J].
CHARNSANGAVEJ, C ;
WALLACE, S ;
WRIGHT, KC ;
CARRASCO, CH ;
GIANTURCO, C .
RADIOLOGY, 1985, 157 (02) :323-324
[8]  
DEBAKEY ME, 1982, SURGERY, V92, P1118
[9]   TRANS-LUMINAL EXPANDABLE NITINOL COIL STENT GRAFTING - PRELIMINARY-REPORT [J].
DOTTER, CT ;
BUSCHMANN, RW ;
MCKINNEY, MK ;
ROSCH, J .
RADIOLOGY, 1983, 147 (01) :259-260
[10]   TRANSLUMINALLY-PLACED COILSPRING ENDARTERIAL TUBE GRAFTS - LONG-TERM PATENCY IN CANINE POPLITEAL ARTERY [J].
DOTTER, CT .
INVESTIGATIVE RADIOLOGY, 1969, 4 (05) :329-+