摘要
The problem of estimation of mean scatterer spacing in an object containing regularly spaced structures is addressed. An autoregressive (AR) spectral estimation method (based on Burg's algorithm) is compared with a conventional fast Fourier transform (FFT) based approach for this task. Regularly spaced structures produce a periodicity in the power spectrum of ultrasonic backscatter. This periodicity is manifested as a peak in the cepstrum. A phantom was constructed for comparison of the two methods. This phantom contained regularly spaced nylon filaments. In addition, it contained randomly positioned glass spheres that produced incoherent backscatter. In an experiment in which this target was interrogated using broadband ultrasound, the AR spectral estimate offered considerable improvement over the FFT when the analysis gate length was on the order of the structural dimension. Advantages included improved resolution, reduction in bias and variance of scatterer spacing estimates, and greater resistance to ringing artifacts. Data was also acquired from human liver in vivo. AR spectral estimates on human data exhibited a decreased dependence on gate length. These results offer promise for enhanced spatial resolution and accuracy in ultrasonic tissue characterization and nondestructive evaluation of materials.
引用
收藏
页码:50 / 58
页数:9
相关论文
共 19 条
[1]  
AHN YB, 1991, IEEE T ULTRASON FERR, V38, P172, DOI 10.1109/58.79600
[2]  
Bogert B.P., 1963, TIME SERIES ANAL, P209
[3]   ULTRASONIC CHARACTERIZATION OF TISSUE STRUCTURE IN THE INVIVO HUMAN-LIVER AND SPLEEN [J].
FELLINGHAM, LL ;
SOMMER, FG .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1984, 31 (04) :418-428
[4]  
FELLINGHAMJOYNT L, THESIS STANFORD U ST
[5]   ON THE USEFULNESS OF SINGULAR VALUE DECOMPOSITION - ARMA MODELS IN DOPPLER ULTRASOUND [J].
FORSBERG, F .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (05) :418-428
[6]   QUANTITATIVE ULTRASONIC-DETECTION AND CLASSIFICATION OF DIFFUSE LIVER-DISEASE - COMPARISON WITH HUMAN OBSERVER PERFORMANCE [J].
GARRA, BS ;
INSANA, MF ;
SHAWKER, TH ;
WAGNER, RF ;
BRADFORD, M ;
RUSSELL, M .
INVESTIGATIVE RADIOLOGY, 1989, 24 (03) :196-203
[7]  
HAYKIN S, 1983, TOPICS APPLIED PHYSI, V34
[8]   ANALYSIS OF ULTRASOUND IMAGE TEXTURE VIA GENERALIZED RICIAN STATISTICS [J].
INSANA, MF ;
WAGNER, RF ;
GARRA, BS ;
BROWN, DG ;
SHAWKER, TH .
OPTICAL ENGINEERING, 1986, 25 (06) :743-748
[9]   PATTERN-RECOGNITION METHODS FOR OPTIMIZING MULTIVARIATE TISSUE SIGNATURES IN DIAGNOSTIC ULTRASOUND [J].
INSANA, MF ;
WAGNER, RF ;
GARRA, BS ;
MOMENAN, R ;
SHAWKER, TH .
ULTRASONIC IMAGING, 1986, 8 (03) :165-180
[10]  
Lizzi F, 1981, 1981 IEEE ULTR S P, P575