QUANTITATIVE ASSESSMENT OF INTERSTITIAL IMPLANTS

被引:108
作者
SAW, CB
SUNTHARALINGAM, N
机构
[1] PITTSBURGH CANC INST,PITTSBURGH,PA 15213
[2] UNIV PITTSBURGH,SCH MED,JOINT RADIAT ONCOL CTR,DEPT RADIAT ONCOL,PITTSBURGH,PA 15261
[3] THOMAS JEFFERSON UNIV,BODINE CTR CANC TREATMENT,DEPT RADIAT ONCOL & NUCL MED,PHILADELPHIA,PA 19107
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1991年 / 20卷 / 01期
关键词
BRACHYTHERAPY; INTERSTITIAL IMPLANTS; DOSIMETRY; DOSE UNIFORMITY;
D O I
10.1016/0360-3016(91)90149-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Quantitative assessment of interstitial implants is proposed using volume versus dose curves and four well-defined dosimetric parameters. The volume versus dose curves, both differential and cumulative, provide quantitative data on the volumes of tissues irradiated to different doses. They also offer a qualitative assessment of the variations in dose delivery. The dose nonuniformity ratio (DNR) quantitatively determines the degree of dose nonuniformity specific to the implant configuration. The dose rate at which the DNR shows a minimum value, if selected as the treatment dose rate, gives an optimized dose distribution. The three volumetric irradiation indices are formulated with respect to a well-defined target volume. They offer quantitative data on the extent to which the implant delivers the prescribed dose to the target volume. These dosimetric parameters determine the degree of coverage of the target volume, dose homogeniety within the target volume, and irradiation of tissues outside the target volume. The method of quantitative assessment is demonstrated using, as examples, an ideal Ir-192 double-plane implant and an actual clinical Ir-192 double-plane breast implant.
引用
收藏
页码:135 / 139
页数:5
相关论文
共 15 条
[1]   A NATURAL VOLUME-DOSE HISTOGRAM FOR BRACHYTHERAPY [J].
ANDERSON, LL .
MEDICAL PHYSICS, 1986, 13 (06) :898-903
[2]  
ANDERSON LL, 1985, ENDOCURIE HYPERTHERM, V1, P9
[3]   CAN WE COMPARE SYSTEMS FOR INTERSTITIAL THERAPY [J].
DUTREIX, A .
RADIOTHERAPY AND ONCOLOGY, 1988, 13 (02) :127-135
[4]  
GOODWIN PN, 1970, PHYSICAL F RADIOLOGY
[5]   SINGLE-PLANE AND DOUBLE-PLANE IR-192 INTERSTITIAL IMPLANTS - IMPLANTATION GUIDELINES AND DOSIMETRY [J].
KWAN, DK ;
KAGAN, AR ;
OLCH, AJ ;
CHAN, PYM ;
HINTZ, BL ;
WOLLIN, M .
MEDICAL PHYSICS, 1983, 10 (04) :456-461
[6]  
Meredith W, 1967, RADIUM DOSAGE MANCHE
[7]  
METCALF D R, 1988, International Journal of Radiation Oncology, Biology, Physics, V15, P189
[8]   A IR-192 NOMOGRAM SYSTEM FOR SINGLE PLANE IMPLANTS [J].
MURPHY, DJ ;
MEMULA, N ;
DOSS, LL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1986, 12 (02) :267-270
[9]  
PAUL JM, 1986, ENDOCURIE HYPERTHERM, V2, P107
[10]   PARIS SYSTEM IN INTERSTITIAL RADIATION-THERAPY [J].
PIERQUIN, B ;
DUTREIX, A ;
PAINE, CH ;
CHASSAGNE, D ;
MARINELLO, G ;
ASH, D .
ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1978, 17 (01) :33-48