BIOMECHANICAL ANALYSIS OF DORSAL PLATE FIXATION IN PROXIMAL PHALANGEAL FRACTURES

被引:9
作者
DAMRON, TA
JEBSON, PJL
RAO, VK
ENGBER, WD
NORDEN, MA
机构
[1] UNIV WISCONSIN HOSP & CLIN,DIV ORTHOPED SURG,MADISON,WI
[2] UNIV WISCONSIN HOSP & CLIN,DEPT PLAST & RECONSTRUCT SURG,MADISON,WI 53792
关键词
D O I
10.1097/00000637-199403000-00008
中图分类号
R61 [外科手术学];
学科分类号
摘要
The biomechanical properties of three minifragment plate and screw systems were compared to determine whether plate systems primarily designed for maxillofacial reconstruction are bio mechanically sound for use in proximal phalangeal fracture fixation. A middiaphyseal transverse osteotomy was created ir each of 30 fresh-frozen human proximal phalanges to simulate an unstable fracture. Each osteotomy was then fixed with four 2.0ml screws through one of three different four-hole minifragment plates in a middorsal position. Plating systems tested included a vitallium plate with self-tapping screws (Luhr), a stainless steel plate with tapped screws (Synthes), and a titanium plate with tapped screws (Synthes). Testing was performed to failure in an apex volar three-point bending mode. The titanium-plated pha langes were the stiffest construct and required the greatest load and total energy absorbed to failure. However, only the load to failure for titanium versus stainless steel was significantly differ ent. Therefore, there is no biomechanical disadvantage to using the titanium or vitallium plate and screw systems in the setting of unstable proximal phalangeal fractures.
引用
收藏
页码:270 / 275
页数:6
相关论文
共 15 条
[1]   THE USE OF MINIPLATES IN CRANIOMAXILLOFACIAL SURGERY [J].
BEALS, SP ;
MUNRO, IR .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1987, 79 (01) :33-38
[2]   THE STABILITY OF INTERNAL-FIXATION IN THE PROXIMAL PHALANX [J].
BLACK, DM ;
MANN, RJ ;
CONSTINE, RM ;
DANIELS, AU .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1986, 11A (05) :672-677
[3]  
BOCHLER U, 1987, CLIN ORTHOPAEDICS, V214, P53
[4]  
DABEZIES EJ, 1986, J HAND SURG A, V11, P284
[5]   FRACTURES OF THE METACARPALS - TREATMENT BY AO SCREW AND PLATE FIXATION [J].
FORD, DJ ;
ELHADIDI, S ;
LUNN, PG ;
BURKE, FD .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1987, 12B (01) :34-37
[6]  
HASTINGS H, 1987, CLIN ORTHOP RELAT R, V214, P37
[7]   A PHALANGEAL FRACTURE MODEL - QUANTITATIVE-ANALYSIS OF RIGIDITY AND FAILURE [J].
MASSENGILL, JB ;
ALEXANDER, H ;
LANGRANA, N ;
MYLOD, A .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1982, 7 (03) :264-270
[8]   BIOMECHANICAL AND FUNCTIONAL TESTING OF PLATE FIXATION DEVICES FOR PROXIMAL PHALANGEAL FRACTURES [J].
NUNLEY, JA ;
KLOEN, P .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (06) :991-998
[9]   COMPARISON OF COMPRESSION AND TORQUE MEASUREMENTS OF SELF-TAPPING AND PRETAPPED SCREWS [J].
PHILLIPS, JH ;
RAHN, BA .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1989, 83 (03) :447-456
[10]   UNSTABLE PHALANGEAL FRACTURES - TREATMENT BY A.O. SCREW AND PLATE FIXATION [J].
PUN, WK ;
CHOW, SP ;
LUK, KDK ;
NGAI, WK ;
PENG, WH ;
OTR, CN ;
CROSBY, C .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (01) :113-117