PHOTO-CROSS-LINKED COPOLYMERS OF 2-HYDROXYETHYL METHACRYLATE, POLY(ETHYLENE GLYCOL) TETRA-ACRYLATE AND ETHYLENE DIMETHACRYLATE FOR IMPROVING BIOCOMPATIBILITY OF BIOSENSORS

被引:132
作者
QUINN, CP [1 ]
PATHAK, CP [1 ]
HELLER, A [1 ]
HUBBELL, JA [1 ]
机构
[1] UNIV TEXAS,DEPT CHEM ENGN,AUSTIN,TX 78712
关键词
BIOCOMPATIBILITY; BIOSENSORS; SUBCUTANEOUS; POLY(ETHYLENE GLYCOL); GLUCOSE OXIDASE;
D O I
10.1016/0142-9612(95)98856-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A copolymer containing 88% 2-hydroxyethyl methacrylate (HEMA), 9% poly(ethylene glycol) (MW 18.5 kDa) tetra-acrylate and 3% ethylene dimethacrylate was prepared and evaluated for use as a biocompatible interface between glucose biosensors and tissue in the rat. The glucose sensor utilizes glucose oxidase that is electrically 'wired' to a gold current collector by a reduction-oxidation polymer. Coatings of the copolymer were crosslinked in situ on the sensors using long wavelength ultraviolet light and 2,2-dimethoxy-2-phenyl-acetophenone as the initiator. The effect these films had on the current response to glucose was measured. Over a glucose concentration range of 0-30 mM, the average percentage decrease in response was 45 +/- 28% (mean +/- 95% confidence interval) at 37 degrees C for films that were about 0.1 mm thick, an acceptable value. Copolymer-treated and control electrodes were implanted in the intrascapular subcutaneous tissue of male Sprague-Dawley rats for three days. The explanted samples were evaluated using scanning electron microscopy. The control electrodes were highly encapsulated with fibrous material, while the copolymer-treated electrodes induced much less encapsulation. The results show this copolymer to be a candidate as a biocompatible coating for electrically wired oxidoreductase-based subcutaneous biosensors.
引用
收藏
页码:389 / 396
页数:8
相关论文
共 19 条
[1]   APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS [J].
ARMOUR, JC ;
LUCISANO, JY ;
MCKEAN, BD ;
GOUGH, DA .
DIABETES, 1990, 39 (12) :1519-1526
[2]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[3]   POLY(VINYL ALCOHOL)-HEPARIN HYDROGELS AS SENSOR CATHETER MEMBRANES [J].
BRINKMAN, E ;
VANDERDOES, L ;
BANTJES, A .
BIOMATERIALS, 1991, 12 (01) :63-70
[4]  
CSOREGI E, 1994, ANAL CHEM, V66, P3131
[5]   SOLUTION TECHNIQUE TO INCORPORATE POLYETHYLENE OXIDE AND OTHER WATER-SOLUBLE POLYMERS INTO SURFACES OF POLYMERIC BIOMATERIALS [J].
DESAI, NP ;
HUBBELL, JA .
BIOMATERIALS, 1991, 12 (02) :144-153
[6]   IMMOBILIZATION OF POLY(ETHYLENE OXIDE) ON POLY(ETHYLENE-TEREPHTHALATE) USING A PLASMA POLYMERIZATION PROCESS [J].
GOMBOTZ, WR ;
GUANGHUI, W ;
HOFFMAN, AS .
JOURNAL OF APPLIED POLYMER SCIENCE, 1989, 37 (01) :91-107
[7]  
GOUGH DA, 1986, T AM SOC ART INT ORG, V32, P148
[8]   INVITRO AND EXVIVO PLATELET INTERACTIONS WITH HYDROPHILIC HYDROPHOBIC POLY(ETHYLENE OXIDE)-POLYSTYRENE MULTIBLOCK COPOLYMERS [J].
GRAINGER, DW ;
NOJIRI, C ;
OKANO, T ;
KIM, SW .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1989, 23 (09) :979-1005
[9]   REDOX POLYMER-FILMS CONTAINING ENZYMES .1. A REDOX-CONDUCTING EPOXY CEMENT - SYNTHESIS, CHARACTERIZATION, AND ELECTROCATALYTIC OXIDATION OF HYDROQUINONE [J].
GREGG, BA ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1991, 95 (15) :5970-5975
[10]   DETERMINATION OF URATE IN UNDILUTED WHOLE-BLOOD BY ENZYME ELECTRODE [J].
KEEDY, FH ;
VADGAMA, P .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (06) :491-499