VISUALIZATION OF BASAL PLEURAL SPACE AND LUNG WITH ADVANCED MULTIPLE BEAM EQUALIZATION RADIOGRAPHY (AMBER)

被引:3
作者
AARTS, NJM
OESTMANN, JW
KOOL, LJS
机构
[1] Department of Diagnostic Radiology, University Hospital Leiden
关键词
THORAX; RADIOGRAPHY; COMPARATIVE STUDY; TECHNIQUE;
D O I
10.1016/0720-048X(93)90011-B
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
During clinical use of AMBER (Advanced Multiple Beam Equalization Radiography) it was frequently felt that the basal lung and pleural space were better appreciated than with standard chest radiography. We aimed to quantify the amount of additional relevant anatomy seen in this part region and to review the normal radiographic anatomy. Four hundred patients without known chest disease were evaluated. Two groups of 200 patients (50% female) were studied with either AMBER or standard chest radiography (140 kVp, 180 cm FFD, Kodak Tmat G film, Lanex regular screen; for both techniques). Visualization of the pleural sinuses (in percent of the transverse thoracic diameter) and the basal pulmonary vessels (4-point scale) was evaluated by a panel of 3 radiologists. The shape of the sinus was traced if sufficiently visible and subjectively evaluated. A significantly (P<0.05) larger segment of the dorsal (41 +/- 34%) and ventral (14 +/- 15%) sinuses was seen with the AMBER technique than with the standard technique (16 +/- 21% and 9 +/- 11%, respectively). Vessel visibility was also significantly (P<0.001) better with AMBER (3.2 +/- 0.6) than with the standard technique (1.9 +/- 0.6). The dorsal sinus showed alternatively a curved or pointed configuration.
引用
收藏
页码:138 / 142
页数:5
相关论文
共 11 条
[1]  
Sorenson, Mitchell, Armstrong, Mann, Bragg, Mann, Tocino, Wojtowycz, Effects of improved contrast on lung-nodule detection: a clinical roc study, Invest Radiol, 22, pp. 772-780, (1987)
[2]  
Herman, Gerson, Hessel, Mayer, Watnick, Blesser, Ozonoff, Disagreements in chest roentgen interpretation, Chest, 68, pp. 278-282, (1975)
[3]  
Herman, Hessel, Accuracy and its relationship to experience in the interpretation of chest radiographs, Invest Radiol, 10, pp. 62-67, (1975)
[4]  
Yerushalmy, The statistical assessment of the variability in observer perception and description of roentgenographic pulmonary shadows, Radiol Clin N Am, 7, pp. 381-392, (1969)
[5]  
Vlasbloem, Schultze Kool, Amber: a scanning multiple beam equalization system for chest radiography, Radiology, 169, pp. 29-34, (1988)
[6]  
Schultze Kool, Busscher, Vlasbloem, Hermans, Van der Merwe, Algra, Herstel, Advanced multiple-beam equalization radiography in chest radiology: A simulated nodule detection study, Radiology, 169, pp. 35-39, (1988)
[7]  
Lachman, A comparison of the posterior boundaries of lungs and pleura as demonstrated on the cadaver and on the roentgenogram of the living, The Anatomical Record, 83, pp. 521-542, (1942)
[8]  
Peltason, Neumann, RöFo, Die Röntgendarstellung der unteren Pleuragrenze, 47, pp. 520-529, (1933)
[9]  
Revesz, Kundell, Graber, The influence of structured noise on the detection of radiologic abnormalities, Invest Radiol, 9, pp. 479-486, (1974)
[10]  
Kelsey, Moseley, Brogdon, Hallberg, Effect of size and position on chest lesion detection, AJR, 129, pp. 205-208, (1977)