INVITRO AND INVIVO INTRAVASCULAR ULTRASOUND IMAGING

被引:16
作者
BARTORELLI, AL [1 ]
NEVILLE, RF [1 ]
KEREN, G [1 ]
POTKIN, BN [1 ]
ALMAGOR, Y [1 ]
BONNER, RF [1 ]
GESSERT, JM [1 ]
LEON, MB [1 ]
机构
[1] NHLBI,CARDIOL BRANCH,BETHESDA,MD 20892
基金
美国国家卫生研究院;
关键词
ULTRASOUND; INTRAVASCULAR IMAGING;
D O I
10.1093/oxfordjournals.eurheartj.a060028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This paper presents our experience with intravascular ultrasound imaging of animal and human arteries in vitro and in vivo using a high-frequency (20 MHz) ultrasound transducer. In vitro, 32 human coronary artery segments were imaged with intravascular ultrasound and compared with corresponding histological sections. Ultrasound and histology measurements correlated significantly (P<0.0001) for coronary artery cross-sectional area (r=0.94), lumen cross-sectional area (r=0.85) and wall thickness (r=0.92). In vivo, 19 sheep and eight human common femoral arteries were imaged and the angiographic lumen diameter of 14 animal and six human arteries was compared to the diameter of the corresponding ultrasound images. Significant correlations were found for lumen diameter in animals and humans (P<0.001, r=0.91 and P<0.0001, r=0.96, respectively). These studies demonstrate that this technique can provide high resolution images of arterial vessels and may have unique advantages in diagnosing atherosclerotic vascular disease and in catheter based therapies. © 1992 The European Society of Cardiology.
引用
收藏
页码:102 / 108
页数:7
相关论文
共 12 条
[1]  
FORRESTER JS, 1989, INTERVENTIONAL CARDI, P36
[2]  
GRONDIN CM, 1974, CIRCULATION, V49, P703
[3]   ARTERIAL-WALL CHARACTERISTICS DETERMINED BY INTRAVASCULAR ULTRASOUND IMAGING - AN INVITRO STUDY [J].
GUSSENHOVEN, EJ ;
ESSED, CE ;
LANCEE, CT ;
MASTIK, F ;
FRIETMAN, P ;
VANEGMOND, FC ;
REIBER, J ;
BOSCH, H ;
VANURK, H ;
ROELANDT, J ;
BOM, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) :947-952
[4]   HIGH-RESOLUTION DYNAMIC ULTRASOUND IMAGING OF THE CAROTID BIFURCATION - A PROSPECTIVE EVALUATION [J].
JAMES, EM ;
EARNEST, F ;
FORBES, GS ;
REESE, DF ;
HOUSER, OW ;
FOLGER, WN .
RADIOLOGY, 1982, 144 (04) :853-858
[5]  
MALLERY JA, 1988, J AM COLL CARDIOL, V2, pA22
[6]   FEASIBILITY OF HIGH-RESOLUTION, INTRAVASCULAR ULTRASONIC-IMAGING CATHETERS [J].
MEYER, CR ;
CHIANG, EH ;
FECHNER, KP ;
FITTING, DW ;
WILLIAMS, DM ;
BUDA, AJ .
RADIOLOGY, 1988, 168 (01) :113-116
[7]   THE DEPENDENCE OF ULTRASONIC-ATTENUATION AND BACKSCATTER ON COLLAGEN CONTENT IN DOG AND RABBIT HEARTS [J].
MIMBS, JW ;
ODONNELL, M ;
BAUWENS, D ;
MILLER, JW ;
SOBEL, BE .
CIRCULATION RESEARCH, 1980, 47 (01) :49-58
[8]   RELATIONSHIP BETWEEN COLLAGEN AND ULTRASONIC-ATTENUATION IN MYOCARDIAL TISSUE [J].
ODONNELL, M ;
MIMBS, JW ;
MILLER, JG .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1979, 65 (02) :512-517
[9]   ULTRASOUND ANGIOSCOPY - REAL-TIME, TWO-DIMENSIONAL, INTRALUMINAL ULTRASOUND IMAGING OF BLOOD-VESSELS [J].
PANDIAN, NG ;
KREIS, A ;
BROCKWAY, B ;
ISNER, JM ;
SACHAROFF, A ;
BOLEZA, E ;
CARO, R ;
MULLER, D .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (07) :493-494
[10]   CORONARY-ARTERY IMAGING WITH INTRAVASCULAR HIGH-FREQUENCY ULTRASOUND [J].
POTKIN, BN ;
BARTORELLI, AL ;
GESSERT, JM ;
NEVILLE, RF ;
ALMAGOR, Y ;
ROBERTS, WC ;
LEON, MB .
CIRCULATION, 1990, 81 (05) :1575-1585