CELL GEOMETRY CONSIDERATIONS FOR THE FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY REMEASUREMENT EXPERIMENT

被引:15
作者
CAMPBELL, VL [1 ]
GUAN, ZQ [1 ]
VARTANIAN, VH [1 ]
LAUDE, DA [1 ]
机构
[1] UNIV TEXAS,DEPT CHEM & BIOCHEM,AUSTIN,TX 78712
关键词
D O I
10.1021/ac00098a030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three cell geometries, closed cubic, closed elongated, and open elongated, are evaluated for optimum remeasurement performance in the Fourier transform ion cyclotron resonance mass spectrometry (FTICR) experiment. The advantages and disadvantages of each cell during normal FTICR operation are discussed. Unit remeasurement efficiency is obtained for the closed elongated cell at similar to 71% of the cell radius, whereas the open elongated cell achieves unit remeasurement at only similar to 18% of the cell radius. The closed cubic cell does not achieve unit remeasurement efficiency at a detectable signal level. A correlation between remeasurement efficiency and the characteristic radial electric field of each trapped ion cell is established. Radial dispersion of the ion cloud is considered the dominant signal loss mechanism in the remeasurement experiment, and cell geometries are examined for optimized sensitivity and unit remeasurement efficiency.
引用
收藏
页码:420 / 425
页数:6
相关论文
共 39 条
[1]   RADIAL ION-TRANSPORT DUE TO RESISTIVE-WALL DESTABILIZATION IN FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 108 (2-3) :255-268
[2]   OPEN TRAPPED ION CELL GEOMETRIES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 112 (2-3) :215-230
[3]   IMPROVED FOURIER-TRANSFORM ION-CYCLOTRON-RESONANCE MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
BEU, SC ;
SENKO, MW ;
QUINN, JP ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (02) :190-192
[4]   ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY [J].
BRUINS, AP ;
COVEY, TR ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2642-2646
[5]   SELECTIVE GENERATION OF CHARGE-DEPENDENT - INDEPENDENT ION ENERGY-DISTRIBUTIONS FROM A HEATED CAPILLARY ELECTROSPRAY SOURCE [J].
CAMPBELL, VL ;
GUAN, ZQ ;
LAUDE, DA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (04) :221-229
[6]  
CAMPBELL VL, 1994, 42ND ASMS C MASS SPE
[7]   MODELING COULOMB EFFECTS IN FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY BY CHARGED DISKS AND CHARGED CYLINDERS [J].
CHEN, SP ;
COMISAROW, MB .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (01) :1-3
[8]   SIMPLE PHYSICAL MODELS FOR COULOMB-INDUCED FREQUENCY-SHIFTS AND COULOMB-INDUCED INHOMOGENEOUS BROADENING FOR LIKE AND UNLIKE IONS IN FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CHEN, SP ;
COMISAROW, MB .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (10) :450-455
[9]   FREQUENCY-SWEEP FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY [J].
COMISARO.MB ;
MARSHALL, AG .
CHEMICAL PHYSICS LETTERS, 1974, 26 (04) :489-490
[10]   FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY [J].
COMISAROW, MB ;
MARSHALL, AG .
CHEMICAL PHYSICS LETTERS, 1974, 25 (02) :282-283