DIOXIN REMOVAL IN A WET SCRUBBER AND DRY PARTICULATE REMOVER

被引:21
作者
RUEGG, H [1 ]
SIGG, A [1 ]
机构
[1] VON ROLL INC,NORCROSS,GA
关键词
D O I
10.1016/0045-6535(92)90499-H
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Chlorinated dioxins and furans (PCDDs and PCDFs), formed by de novo synthesis, can be removed fran the flue gas stream by using activated carbon. In a series of tests conducted at full-scale municipal solid waste incinerators, the effects of activated carbon injection on PCDD and PCDF emissions was assessed. Also evaluated was the impact of ammonia on the PCDD and PCDF formation process within these systems.