PROLONGED SUPPORT OF WORKING RABBIT HEARTS USING FLUOSOL-43 OR ERYTHROCYTE MEDIA

被引:22
作者
SEGEL, LD
ENSUNSA, JL
BOYLE, WA
机构
[1] UNIV CALIF DAVIS, SCH MED, DEPT INTERNAL MED, DAVIS, CA 95616 USA
[2] UNIV CALIF DAVIS, SCH MED, DEPT ANESTHESIOL, DAVIS, CA 95616 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY | 1987年 / 252卷 / 02期
关键词
D O I
10.1152/ajpheart.1987.252.2.H349
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We compared the perfluorochemical emulsion Fluosol-43 and an erythrocyte-based solution as support media for ex vivo working rabbit hearts functioning with a physiological workload. Both groups of hearts (n = 5/group) exhibited stable function (left ventricular peak systolic pressure, peak rates of left ventricular pressure rise and relaxation, aortic flow, peak aortic flow rate, stroke work, and peak power) of the first 6 h of perfusion. Coronary flow, coronary venous O2 content, and O2 supply-to-demand ratio declined similarly in both groups during the first 6 h. Both groups of hearts preferentially utilized pyruvate to glucose. The Fluosol-43-perfused haert had higher heart rate, left ventricular peak systolic pressure, peak rate of left ventricular pressure rise, aortic flow, coronary flow, and myocardial O2 consumption compared with the erythrocyte-perfused hearts. The Fluosol-43 hearts produced more lactate and released more creatine phosphokinase than did the erythrocyte-perfused hearts, but the rates were low and not throughout perfusion, indicating that the hearts were not progressively ischemic. After the first 6 h, function of the Fluosol-43 hearts declined, resulting in their earlier failure compared with the erythrocyte-perfused hearts. The data indicate that 1) Fluosol-43 had sufficient O2-carrying capacity to support stable function of a rabbit heart a physiological workload for 6 h, and 2) differences in function and ex vivo longevity of the two groups of hearts suggested that a component or contaminant of Fluosol-43 altered sarcolemma function and/or that a component needed for membrane integrity was lacking in the Fluosol-3 perfusate.
引用
收藏
页码:H349 / H359
页数:11
相关论文
共 37 条
  • [1] ENHANCED OXYGEN UNLOADING BY AN INTERDIMERICALLY CROSSLINKED HEMOGLOBIN IN AN ISOLATED PERFUSED RABBIT HEART
    BENESCH, R
    TRINER, L
    BENESCH, RE
    KWONG, S
    VEROSKY, M
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1984, 81 (09): : 2941 - 2943
  • [2] BLUNT MH, 1975, BLOOD SHEEP, P33
  • [3] SQUARE-PULSE FLOW METHOD FOR MEASURING CHARACTERISTICS OF ARTERIAL BED
    BOTTOMLEY, MG
    MAINWOOD, GW
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (03) : 425 - 433
  • [4] CRYSTALLOID AND PERFLUOROCHEMICAL PERFUSATES IN AN ISOLATED WORKING RABBIT HEART PREPARATION
    CHEMNITIUS, JM
    BURGER, W
    BING, RJ
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1985, 249 (02): : H285 - H292
  • [5] CHIONG MA, 1985, CAN J PHYSL PHARM, V58, P469
  • [6] REVERSAL OF THE ENDOCRINE TOXICITY OF COMMERCIALLY PRODUCED PERFLUOROCHEMICAL EMULSION
    CHUBB, C
    [J]. BIOLOGY OF REPRODUCTION, 1985, 33 (04) : 854 - 858
  • [7] CURRY FRE, 1985, FED PROC, V44, P2610
  • [8] CZOK R, 1974, METHOD ENZYMAT AN, V3, P1447
  • [9] Dhindsa DS, 1970, RED CELL METABOLISM, P229
  • [10] EFFECT OF GLUCOSE AND OF FATTY-ACID ON RHYTHM, ENZYME-RELEASE AND OXYGEN-UPTAKE IN ISOLATED PERFUSED WORKING RAT-HEART WITH CORONARY-ARTERY LIGATION
    DIDIER, JP
    MOREAU, D
    OPIE, LH
    [J]. JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 1980, 12 (11) : 1191 - 1206