Total hip arthroplasty using the Zweymuller stem implanted without cement - A prospective study of consecutive patients with minimum 3-year follow-up period

被引:38
作者
Huo, MH [1 ]
Martin, RP [1 ]
Zatorski, LE [1 ]
Keggi, KJ [1 ]
机构
[1] JOHNS HOPKINS UNIV,SCH MED,DEPT ORTHOPAED SURG,BALTIMORE,MD
关键词
total hip arthroplasty; cementless; Zweymuller; osteolysis;
D O I
10.1016/S0883-5403(05)80077-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A prospective study was undertaken over a 2-year period to evaluate the clinical efficacy of using the Zweymuller femoral component (Allopro, Berne, Switzerland) in cementless total hip arthroplasty. Forty consecutive patients (46 hips) were included for final evaluation. Ninety-four percent of the femurs were classified as Dorr class B or C before surgery. The mean follow-up period was 50 months (median, 48 months). Ninety-eight percent of the hips were rated good or excellent clinically. No stem was classified as definitely loose. No hip has required any reoperation. There was no incidence of femoral or acetabular osteolysis up to 6 years.
引用
收藏
页码:793 / 799
页数:7
相关论文
共 21 条
[1]  
Callaghan, Dysart, Savory, The uncemented porous-coated anatomic total hip replacement: two-year results of a prospective consecutive series, J Bone Joint Surg, 70 A, (1988)
[2]  
Maloney, Harris, Comparison of a hybrid with an uncemented total hip replacement: a retrospective matched-pair study, J Bone Joint Surg, 72 A, (1990)
[3]  
Wixson, Stulberg, Mehlhoff, Total hip replacement with cemented, uncemented, and hybrid prostheses: a comparison of clinical and radiographic results at two to four years, J Bone Joint Surg, 73 A, (1991)
[4]  
Maloney, Jasty, Harris, Et al., Endosteal erosion in association with stable uncemented femoral components, J Bone Joint Surg, 72 A, (1990)
[5]  
Svensson, Mathiesen, Reinholt, Blomgren, Formation of a fulminant soft-tissue pseudotumor after uncemented hip arthroplasty: a case report, J Bone Joint Surg, 70 A, (1988)
[6]  
Tanzer, Maloney, Jasty, Harris, The progression of femoral cortical osteolysis in association with total hip arthroplasty without cement, J Bone Joint Surg, 74 A, (1992)
[7]  
Zweymuller, A cementless titanium hip endoprosthesis system based on press-fit fixation: basic research and clinical results, Instr Course Lect Note, 36, (1986)
[8]  
Zweymuller, Lintner, Semlitsch, Biologic fixation of a press-fit titanium hip joint endoprosthesis, Clin Orthop Relat Res, 235, (1988)
[9]  
Keggi, Huo, Zatorski, Anterior approach to total hip replacement surgical technique and clinical results of our first one thousand cases using non-cemented prostheses, Yale J Biol Med, 66, (1993)
[10]  
Harris, Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty: an end-result study using a new method of results evaluation, J Bone Joint Surg, 51 A, (1969)