CONDUCTANCE VOLUMETRIC MODEL OF AN ECCENTRICALLY POSITIONED CATHETER WITHIN A 3-COMPARTMENT ELLIPSOIDAL VENTRICLE

被引:5
作者
KUN, S
PEURA, RA
机构
[1] Worcester Polytechnic Institute, Biomedical Engineering Department, Worcester
关键词
D O I
10.1109/10.237679
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a mathematical model of the electric field generated and resistance measured by a conductance catheter within a three-compartment ellipsoidal approximation of a cardiac ventricle. The model is based on a novel combination of analytical and numerical techniques. The numerical component of the model predicts displacement of the catheter along the central longitudinal ventricular axis, as well as eccentric positions off that axis. The analytical component of the model enables interactive definition of model parameters during simulation. This versatile combination enables performance of validation studies that include simulations of various catheter movements within a ventricle of changing geometry. The results of our simulation studies agree with the results of previous investigators studying ex-vivo systems.
引用
收藏
页码:589 / 593
页数:5
相关论文
共 10 条
  • [1] CONTINUOUS STROKE VOLUME AND CARDIAC-OUTPUT FROM INTRAVENTRICULAR DIMENSIONS OBTAINED WITH IMPEDANCE CATHETER
    BAAN, J
    JONG, TTA
    KERKHOF, PLM
    MOENE, RJ
    VANDIJK, AD
    VANDERVELDE, ET
    KOOPS, J
    [J]. CARDIOVASCULAR RESEARCH, 1981, 15 (06) : 328 - 334
  • [2] ACCURACY OF VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN ISOLATED, EJECTING CANINE HEARTS
    BURKHOFF, D
    VANDERVELDE, E
    KASS, D
    BAAN, J
    MAUGHAN, WL
    SAGAWA, K
    [J]. CIRCULATION, 1985, 72 (02) : 440 - 447
  • [3] VOLUME CONDUNCTANCE CATHETER
    GLANTZ, SA
    BOLTWOOD, CM
    APPLEYARD, RF
    APPLEGATE, RJ
    CHENG, CP
    LITTLE, WC
    [J]. CIRCULATION, 1990, 81 (06) : 2028 - 2028
  • [4] KUN S, 1989, THESIS WORCESTER POL
  • [5] LODICO KF, 1991, 17TH P IEEE ANN NE B, P131
  • [6] COMPUTATION OF THE INPUT IMPEDANCES OF A CATHETER FOR CARDIAC VOLUMETRY
    MUR, G
    BAAN, J
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (06) : 448 - 453
  • [7] Salo R. W., 1989, Automedica, V11, P299
  • [8] MEASUREMENT OF VENTRICULAR VOLUME BY INTRACARDIAC IMPEDANCE - THEORETICAL AND EMPIRICAL APPROACHES
    SALO, RW
    WALLNER, TG
    PEDERSON, BD
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) : 189 - 195
  • [9] Spinelli J. C., 1989, Automedica, V11, P281
  • [10] CONDUCTIVITY AND GEOMETRICAL FACTORS AFFECTING VOLUME MEASUREMENTS WITH AN IMPEDANCIMETRIC CATHETER
    SPINELLI, JC
    VALENTINUZZI, ME
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1986, 24 (05) : 460 - 464