MEASUREMENT OF INVERTED ELECTRICAL-CONDUCTIVITY PROFILES USING ELECTROMAGNETIC INDUCTION

被引:65
作者
CORWIN, DL
RHOADES, JD
机构
关键词
ELECTRODES - Applications - ELECTROMAGNETIC FIELD MEASUREMENT - Processing;
D O I
10.2136/sssaj1984.03615995004800020011x
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
Due to sharp discrepancies in the relative response of the horizontal and vertical coil configurations of the Geonics Limited EM-38 electromagnetic induction soil conductivity meter for the top 15 cm of soil, the accuracy of measurement of bulk electrical conductivity for soil having a high surface electrical conductivity relative to deeper depths (i. e. , an inverted electrical conductivity profile) has been unreliable. Two new approaches have been developed to compensate for these discrepancies, either through compensations in the vertical coil configuration response curve or the reestablishment of EM//0//,//H adjustment curves utilizing data solely from inverted conductivity profiles.
引用
收藏
页码:288 / 291
页数:4
相关论文
共 8 条