RASTER-ELECTRON-MICROSCOPIC INVESTIGATIONS IN LARGE-BORE CATHETERS FOR EXTRACORPOREAL DETOXIFICATION

被引:5
作者
BAMBAUER, R
MESTRES, P
PIROUNG, KJ
机构
关键词
D O I
10.1177/039139889001301007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Large bore catheters (n = 42, 31 patients) which remained in position for a period of between 2 to 73 days (x̄ = 26.8 days/patients) were investigated with raster electron-microscopy (scanning electron micrographic: SEM) and for bacterial colonisation. Microbiological findings indicated colonisation of the intravascular large bore catheters in 8 out of 42 catheters (19%). SEM morphological investigation showed bacterial colonisation in only 3 catheters (7%). The 3 different catheter materials had small deposits of fibrin and protein on the inner and outer surfaces after 2 days. This second layer covered the entire surface after 3 days and increased to a thickness of 3-60 μm in the following days. In this matrix erythrocytes, thrombocytes and granulocytes could also been seen.
引用
收藏
页码:667 / 671
页数:5
相关论文
共 6 条
  • [1] BAMBAUER R, 1982, DIALYSIS TRANSPLANT, V11, P766
  • [2] A MORPHOLOGICAL-STUDY OF BACTERIAL-COLONIZATION OF INTRAVENOUS CANNULAE
    CHEESBROUGH, JS
    ELLIOTT, TSJ
    FINCH, RG
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 1985, 19 (02) : 149 - 157
  • [3] HINRICHSEN K, 1979, VERH ANAT GES, V73, P483
  • [4] JOHN U, 1986, KRH HYG INF VERH, V2, P51
  • [5] MESTRES P, 1983, ANAT EMBRYOL, P433
  • [6] PETERS G, 1986, FAC, V3, P469