HEMOLYSIS INVIVO BY THERAPEUTIC INTENSITIES OF ULTRASOUND

被引:21
作者
WILLIAMS, AR [1 ]
MILLER, DL [1 ]
GROSS, DR [1 ]
机构
[1] TEXAS A&M UNIV, COLL VET MED, DEPT VET PHYSIOL & PHARMACOL, COLLEGE STN, TX 77843 USA
关键词
D O I
10.1016/0301-5629(86)90221-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Therapeutic intensities of MHz ultrasound directed at the upper abdominal area of rats in vivo resulted in damage to the circulating red blood cells. This damage was detected as free haemoglobin in the plasma as well as microspheres and spherocytic cell fragments which are characteristically produced when blood is heated to more than 49.degree. C. The magnitude of this effect increased with increasing frequency of the ultrasound and was dependent upon the time-averaged intensity, even when the ultrasound was delivered as bursts of high spatial peak intensities. Thermal lesions were found above 10 W/cm2 SP at 1 MHz and above 3 W/cm2 SP at 3.4 MHz. These results show that the observed blood cell damage is primarily a thermal effect which occurs as the blood perfuses anatomical structures which are being heated by the ultrasound beam.
引用
收藏
页码:501 / 509
页数:9
相关论文
共 17 条
[1]   FINITE-AMPLITUDE EFFECTS ON THE THRESHOLDS FOR LESION PRODUCTION IN TISSUES BY UNFOCUSED ULTRASOUND [J].
CARSTENSEN, EL ;
BECROFT, SA ;
LAW, WK ;
BARBEE, DB .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1981, 70 (02) :302-309
[2]   ABSENCE OF PLATELET DAMAGE INVIVO FOLLOWING THE EXPOSURE OF NON-TURBULENT BLOOD TO THERAPEUTIC ULTRASOUND [J].
CHATER, BC ;
WILLIAMS, AR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (01) :85-87
[3]  
COWDEN J. W., 1963, EXPTL AND MOLECULAR PATHOL, V2, P367, DOI 10.1016/0014-4800(63)90017-0
[4]   A SEARCH FOR ULTRASONIC CAVITATION WITHIN THE CANINE CARDIOVASCULAR-SYSTEM [J].
GROSS, DR ;
MILLER, DL ;
WILLIAMS, AR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (01) :85-97
[5]   BIOLOGICAL MEMBRANE RUPTURE AND A PHASE-TRANSITION MODEL [J].
KRIZAN, JE ;
WILLIAMS, AR .
NATURE-NEW BIOLOGY, 1973, 246 (152) :121-122
[6]   THE EFFECTS OF ULTRASOUND INVIVO ON MOUSE-LIVER IN CONTACT WITH AN AQUEOUS COUPLING MEDIUM [J].
MARTIN, CJ ;
GREGORY, DW ;
HODGKISS, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1981, 7 (03) :253-265
[7]   FURTHER INVESTIGATIONS OF ATP RELEASE FROM HUMAN-ERYTHROCYTES EXPOSED TO ULTRASONICALLY ACTIVATED GAS-FILLED PORES [J].
MILLER, DL ;
WILLIAMS, AR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1983, 9 (03) :297-307
[9]   CHARACTERIZATION OF CAVITATION IN A FLOW-THROUGH EXPOSURE CHAMBER BY MEANS OF A RESONANT BUBBLE DETECTOR [J].
MILLER, DL ;
WILLIAMS, AR ;
GROSS, DR .
ULTRASONICS, 1984, 22 (05) :224-230
[10]   PREDICTION OF NON-LINEAR ACOUSTIC EFFECTS AT BIOMEDICAL FREQUENCIES AND INTENSITIES [J].
MUIR, TG ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1980, 6 (04) :345-357