HEAT AND FLUID-FLOW IN RECTANGULAR SOLAR AIR HEATER DUCTS HAVING TRANSVERSE RIB ROUGHNESS ON ABSORBER PLATES

被引:191
作者
GUPTA, D [1 ]
SOLANKI, SC [1 ]
SAINI, JS [1 ]
机构
[1] UNIV ROORKEE,DEPT MECH & IND ENGN,ROORKEE 247667,UTTAR PRADESH,INDIA
关键词
D O I
10.1016/0038-092X(93)90039-Q
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An experimental investigation has been carried out to determine the effect of transverse wire roughness on heat and fluid flow characteristics in transitionally rough flow region (5 < e+ < 70) for rectangular solar air heater ducts with an absorber plate having transverse wire roughness on its underside. The investigation covered a Reynolds number range of 3000-18000 for a duct aspect ratio of 6.8-11.5, relative roughness height of 0.018-0.052 ata relative roughness pitch of 10 encompassing a range of roughness Reynolds number between 5-70. Simple correlations for a Nusselt number and friction factor have been developed in terms of geometrical parameters of roughness, duct cross section, and the flow Reynolds number.
引用
收藏
页码:31 / 37
页数:7
相关论文
共 18 条
[1]   IMPROVEMENT OF THE EFFICIENCY OF A BARE SOLAR COLLECTOR BY MEANS OF TURBULENCE PROMOTERS [J].
CORTES, A ;
PIACENTINI, R .
APPLIED ENERGY, 1990, 36 (04) :253-261
[2]  
Dipprey D.F., 1963, INT J HEAT MASS TRAN, V6, P329, DOI [10.1016/0017-9310(63)90097-8, DOI 10.1016/0017-9310(63)90097-8]
[3]  
DONNE MD, 1979, INT J HEAT MASS TRAN, V22, P583
[4]   DEVELOPING HEAT-TRANSFER IN RECTANGULAR CHANNELS WITH RIB TURBULATORS [J].
HAN, JC ;
PARK, JS .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1988, 31 (01) :183-195
[5]   HEAT-TRANSFER AND FRICTION IN CHANNELS WITH 2 OPPOSITE RIB-ROUGHENED WALLS [J].
HAN, JC .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1984, 106 (04) :774-781
[6]   TURBULENT HEAT AND MASS-TRANSFER FROM A WALL WITH PARALLEL ROUGHNESS RIDGES [J].
KADER, BA ;
YAGLOM, AM .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1977, 20 (04) :345-357
[7]   EFFECTS OF V-SHAPED RIB ARRAYS ON TURBULENT HEAT-TRANSFER AND FRICTION OF FULLY-DEVELOPED FLOW IN A SQUARE CHANNEL [J].
LAU, SC ;
KUKREJA, RT ;
MCMILLIN, RD .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1991, 34 (07) :1605-1616
[8]  
NIKURADSE J, 1950, NACA TM1292
[9]   EFFECT OF ARTIFICIAL ROUGHNESS ON HEAT-TRANSFER AND FRICTION FACTOR IN A SOLAR AIR HEATER [J].
PRASAD, BN ;
SAINI, JS .
SOLAR ENERGY, 1988, 41 (06) :555-560
[10]   HEAT-TRANSFER CHARACTERISTICS OF A SOLAR AIR HEATER USED FOR DRYING PURPOSES [J].
PRASAD, K ;
MULLICK, SC .
APPLIED ENERGY, 1983, 13 (02) :83-93