LIQUID-NITROGEN COOLED WINDOW FOR HIGH-FREQUENCY PLASMA-HEATING

被引:7
作者
HAFNER, HE
BOJARSKY, E
HECKERT, K
NORAJITRA, P
REISER, H
机构
[1] Kernforschungszentrum Karlsruhe GmbH, Institute of Materials Science, D-76021 Karlsruhe 1
关键词
D O I
10.1016/0022-3115(94)90990-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Plasma heating in nuclear fusion reactors by feed of millimeter waves from gyrotrons calls for effective and reliable high-vacuum-tight window systems with preferably 1 MW power transmission as a major prerequisite. Experiments were performed in which the functionality of the chosen concept was proved and the design calculations were verified.
引用
收藏
页码:1035 / 1038
页数:4
相关论文
共 5 条
[1]  
ALEKSANDROV NL, 1992, 4TH P RUSS GERM M EC
[2]  
FIX AS, 1992, 4TH P RUSS GERM M EC
[3]  
HEIDINGER R, 1994, J NUCL MATER, V212
[4]  
NORAJITRA P, 1991, KFK4930 REP
[5]  
Touloukian Y. S., 1970, THERMOPHYSICAL PROPE, V2