POTENTIAL ERRORS IN PULSE OXIMETRY .1. PULSE OXIMETER EVALUATION
被引:112
作者
:
RALSTON, AC
论文数:
0
引用数:
0
h-index:
0
机构:
ROYAL ADELAIDE HOSP,DEPT ANAESTHESIA & INTENS CARE,N TERR,ADELAIDE,SA 5000,AUSTRALIA
ROYAL ADELAIDE HOSP,DEPT ANAESTHESIA & INTENS CARE,N TERR,ADELAIDE,SA 5000,AUSTRALIA
RALSTON, AC
[
1
]
WEBB, RK
论文数:
0
引用数:
0
h-index:
0
机构:
ROYAL ADELAIDE HOSP,DEPT ANAESTHESIA & INTENS CARE,N TERR,ADELAIDE,SA 5000,AUSTRALIA
ROYAL ADELAIDE HOSP,DEPT ANAESTHESIA & INTENS CARE,N TERR,ADELAIDE,SA 5000,AUSTRALIA
WEBB, RK
[
1
]
RUNCIMAN, WB
论文数:
0
引用数:
0
h-index:
0
机构:
ROYAL ADELAIDE HOSP,DEPT ANAESTHESIA & INTENS CARE,N TERR,ADELAIDE,SA 5000,AUSTRALIA
ROYAL ADELAIDE HOSP,DEPT ANAESTHESIA & INTENS CARE,N TERR,ADELAIDE,SA 5000,AUSTRALIA
RUNCIMAN, WB
[
1
]
机构
:
[1]
ROYAL ADELAIDE HOSP,DEPT ANAESTHESIA & INTENS CARE,N TERR,ADELAIDE,SA 5000,AUSTRALIA
来源
:
ANAESTHESIA
|
1991年
/ 46卷
/ 03期
关键词
:
EQUIPMENT;
PULSE OXIMETER;
MEASUREMENT;
D O I
:
10.1111/j.1365-2044.1991.tb09410.x
中图分类号
:
R614 [麻醉学];
学科分类号
:
100217 ;
摘要
:
There is no absolute reference for oxygen saturation, although multiwavelength in vitro oximeters are accepted as the ‘gold standard’. Regardless of whether fractional or functional saturation is used by manufacturers to calibrate their oximeters, evaluation against fractional saturation is recommended since this is the clinically relevant variable. The use of standard notation and comparisons based on bias and precision is recommended. The accuracy of pulse oximetry is intrinsically limited by the use of only two wavelengths, and is dependent on the initial calibration population. The empirical algorithms used to convert the signal to its ‘readout value’ and the quality control of hardware may both be important sources of variability between oximeters. Change in blood temperature may introduce errors in pulse oximeter and in vitro oximeter saturation readings, but these will be clinically insignificant. Changes in blood pH should not decrease pulse oximetry accuracy. Copyright © 1991, Wiley Blackwell. All rights reserved
引用
收藏
页码:202 / 206
页数:5
相关论文
共 16 条
[1]
EFFECTS OF METHEMOGLOBINEMIA ON PULSE OXIMETRY AND MIXED VENOUS OXIMETRY
BARKER, SJ
论文数:
0
引用数:
0
h-index:
0
BARKER, SJ
TREMPER, KK
论文数:
0
引用数:
0
h-index:
0
TREMPER, KK
HYATT, J
论文数:
0
引用数:
0
h-index:
0
HYATT, J
[J].
ANESTHESIOLOGY,
1989,
70
(01)
: 112
-
117
[2]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
BLAND, JM
论文数:
0
引用数:
0
h-index:
0
机构:
NORTHWICK PK HOSP, MRC, CLIN RES CTR, DIV MED STAT, WATFORD RD, HARROW HA1 3UJ, MIDDX, ENGLAND
BLAND, JM
ALTMAN, DG
论文数:
0
引用数:
0
h-index:
0
机构:
NORTHWICK PK HOSP, MRC, CLIN RES CTR, DIV MED STAT, WATFORD RD, HARROW HA1 3UJ, MIDDX, ENGLAND
ALTMAN, DG
[J].
LANCET,
1986,
1
(8476)
: 307
-
310
[3]
A COMPARISON OF THE PERFORMANCE OF 20 PULSE OXIMETERS UNDER CONDITIONS OF POOR PERFUSION
CLAYTON, DG
论文数:
0
引用数:
0
h-index:
0
机构:
Head of Department, University of Adelaide, Australian Patient Safety Foundation, Adelaide, South Australia, 5001
CLAYTON, DG
WEBB, RK
论文数:
0
引用数:
0
h-index:
0
机构:
Head of Department, University of Adelaide, Australian Patient Safety Foundation, Adelaide, South Australia, 5001
WEBB, RK
RALSTON, AC
论文数:
0
引用数:
0
h-index:
0
机构:
Head of Department, University of Adelaide, Australian Patient Safety Foundation, Adelaide, South Australia, 5001
RALSTON, AC
DUTHIE, D
论文数:
0
引用数:
0
h-index:
0
机构:
Head of Department, University of Adelaide, Australian Patient Safety Foundation, Adelaide, South Australia, 5001
DUTHIE, D
RUNCIMAN, WB
论文数:
0
引用数:
0
h-index:
0
机构:
Head of Department, University of Adelaide, Australian Patient Safety Foundation, Adelaide, South Australia, 5001
RUNCIMAN, WB
[J].
ANAESTHESIA,
1991,
46
(01)
: 3
-
10
[4]
Emergency Care Research Institute, 1989, HLTH DEVICES, V18, P185
[5]
REUSING THE NELLCOR PULSE PROBE - CLARIFICATION
KAO, YJ
论文数:
0
引用数:
0
h-index:
0
机构:
TEXAS TECH UNIV,HLTH SCI CTR,PEDIAT,LUBBOCK,TX 79430
TEXAS TECH UNIV,HLTH SCI CTR,PEDIAT,LUBBOCK,TX 79430
KAO, YJ
BADGWELL, JM
论文数:
0
引用数:
0
h-index:
0
机构:
TEXAS TECH UNIV,HLTH SCI CTR,PEDIAT,LUBBOCK,TX 79430
TEXAS TECH UNIV,HLTH SCI CTR,PEDIAT,LUBBOCK,TX 79430
BADGWELL, JM
[J].
ANESTHESIOLOGY,
1987,
67
(05)
: 866
-
866
[6]
LAMBERTSEN CJ, 1974, MED PHYSL, V2, P1399
[7]
MUNLEY AJ, 1989, LANCET, V1, P1048
[8]
PULSE OXIMETRY - TECHNICAL ASPECTS OF MACHINE-DESIGN
POLOGE, JA
论文数:
0
引用数:
0
h-index:
0
POLOGE, JA
[J].
INTERNATIONAL ANESTHESIOLOGY CLINICS,
1987,
25
(03)
: 137
-
153
[9]
REUSING THE NELLCOR PULSE OXIMETER PROBE - IS IT WORTH THE SAVINGS
RACYS, V
论文数:
0
引用数:
0
h-index:
0
RACYS, V
NAHRWOLD, ML
论文数:
0
引用数:
0
h-index:
0
NAHRWOLD, ML
[J].
ANESTHESIOLOGY,
1987,
66
(05)
: 713
-
713
[10]
Roughton F. J. W., 1964, HANDBOOK PHYSIOLOG 3, V1, P767
←
1
2
→
共 16 条
[1]
EFFECTS OF METHEMOGLOBINEMIA ON PULSE OXIMETRY AND MIXED VENOUS OXIMETRY
BARKER, SJ
论文数:
0
引用数:
0
h-index:
0
BARKER, SJ
TREMPER, KK
论文数:
0
引用数:
0
h-index:
0
TREMPER, KK
HYATT, J
论文数:
0
引用数:
0
h-index:
0
HYATT, J
[J].
ANESTHESIOLOGY,
1989,
70
(01)
: 112
-
117
[2]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
BLAND, JM
论文数:
0
引用数:
0
h-index:
0
机构:
NORTHWICK PK HOSP, MRC, CLIN RES CTR, DIV MED STAT, WATFORD RD, HARROW HA1 3UJ, MIDDX, ENGLAND
BLAND, JM
ALTMAN, DG
论文数:
0
引用数:
0
h-index:
0
机构:
NORTHWICK PK HOSP, MRC, CLIN RES CTR, DIV MED STAT, WATFORD RD, HARROW HA1 3UJ, MIDDX, ENGLAND
ALTMAN, DG
[J].
LANCET,
1986,
1
(8476)
: 307
-
310
[3]
A COMPARISON OF THE PERFORMANCE OF 20 PULSE OXIMETERS UNDER CONDITIONS OF POOR PERFUSION
CLAYTON, DG
论文数:
0
引用数:
0
h-index:
0
机构:
Head of Department, University of Adelaide, Australian Patient Safety Foundation, Adelaide, South Australia, 5001
CLAYTON, DG
WEBB, RK
论文数:
0
引用数:
0
h-index:
0
机构:
Head of Department, University of Adelaide, Australian Patient Safety Foundation, Adelaide, South Australia, 5001
WEBB, RK
RALSTON, AC
论文数:
0
引用数:
0
h-index:
0
机构:
Head of Department, University of Adelaide, Australian Patient Safety Foundation, Adelaide, South Australia, 5001
RALSTON, AC
DUTHIE, D
论文数:
0
引用数:
0
h-index:
0
机构:
Head of Department, University of Adelaide, Australian Patient Safety Foundation, Adelaide, South Australia, 5001
DUTHIE, D
RUNCIMAN, WB
论文数:
0
引用数:
0
h-index:
0
机构:
Head of Department, University of Adelaide, Australian Patient Safety Foundation, Adelaide, South Australia, 5001
RUNCIMAN, WB
[J].
ANAESTHESIA,
1991,
46
(01)
: 3
-
10
[4]
Emergency Care Research Institute, 1989, HLTH DEVICES, V18, P185
[5]
REUSING THE NELLCOR PULSE PROBE - CLARIFICATION
KAO, YJ
论文数:
0
引用数:
0
h-index:
0
机构:
TEXAS TECH UNIV,HLTH SCI CTR,PEDIAT,LUBBOCK,TX 79430
TEXAS TECH UNIV,HLTH SCI CTR,PEDIAT,LUBBOCK,TX 79430
KAO, YJ
BADGWELL, JM
论文数:
0
引用数:
0
h-index:
0
机构:
TEXAS TECH UNIV,HLTH SCI CTR,PEDIAT,LUBBOCK,TX 79430
TEXAS TECH UNIV,HLTH SCI CTR,PEDIAT,LUBBOCK,TX 79430
BADGWELL, JM
[J].
ANESTHESIOLOGY,
1987,
67
(05)
: 866
-
866
[6]
LAMBERTSEN CJ, 1974, MED PHYSL, V2, P1399
[7]
MUNLEY AJ, 1989, LANCET, V1, P1048
[8]
PULSE OXIMETRY - TECHNICAL ASPECTS OF MACHINE-DESIGN
POLOGE, JA
论文数:
0
引用数:
0
h-index:
0
POLOGE, JA
[J].
INTERNATIONAL ANESTHESIOLOGY CLINICS,
1987,
25
(03)
: 137
-
153
[9]
REUSING THE NELLCOR PULSE OXIMETER PROBE - IS IT WORTH THE SAVINGS
RACYS, V
论文数:
0
引用数:
0
h-index:
0
RACYS, V
NAHRWOLD, ML
论文数:
0
引用数:
0
h-index:
0
NAHRWOLD, ML
[J].
ANESTHESIOLOGY,
1987,
66
(05)
: 713
-
713
[10]
Roughton F. J. W., 1964, HANDBOOK PHYSIOLOG 3, V1, P767
←
1
2
→