VARIABLES AFFECTING THE ACCURACY OF STEREOTAXIC LOCALIZATION USING COMPUTERIZED-TOMOGRAPHY

被引:60
作者
BUCHOLZ, RD [1 ]
HO, HW [1 ]
RUBIN, JP [1 ]
机构
[1] ST LOUIS UNIV,SCH MED,DEPT MED,DIV NEUROL SURG,ST LOUIS,MO 63104
关键词
COMPUTER TECHNOLOGY; IMAGING; STEREOTAXIS; COMPUTERIZED TOMOGRAPHY;
D O I
10.3171/jns.1993.79.5.0667
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Stereotactic localization using computerized tomography (CT) is increasingly employed to guide neurosurgical procedures in crucial areas of the brain such as the brain stem. This technique allows the surgeon to resect a lesion in its entirety while sparing critical areas of the brain. Thus, the parameters used for scanning should be selected for maximum accuracy. While the small pixel size of CT scanners suggests a high degree of precision in localization, there have been few systematic studies of this accuracy. The authors have studied the amount of error in localization created by variables such as CT scan thickness, interscan spacing, size of lesion, and method of computation when using the Brown-Roberts-Wells (BRW) stereotactic system. Over 1000 CT scans were made of a phantom composed of spheres of differing diameter and location. The CT slice thickness was varied from 1.5 to 5.0 mm, and interscan spacing was varied from 0.5 to 3.0 mm. The coordinates of the center of the spheres were calculated independently using the laptop computer supplied with the unit and also by a stereotactic computer which automatically calculates the center of the fiducials. The actual BRW coordinates of the sphere center were obtained using the phantom base and were then compared to the computer-calculated coordinates to determine error in localization. Variables with a significant effect on error included the scan thickness, interscan spacing, and sphere size. The mean error decreased 23% as the scan thickness decreased from 5.0 to 1.5 mm and 45% as the interscan spacing decreased from 3.0 to 0.5 mm. Mean error was greatest for the smallest sphere sizes. The two computational methods did not differ in error. This study suggests that, for critical areas of the brain or for small lesions, a scan thickness of 1.5 mm and interscan spacing of 0.5 mm should be employed.
引用
收藏
页码:667 / 673
页数:7
相关论文
共 19 条
[1]   RERUPTURE OF INTRACRANIAL ANEURYSMS DURING ANGIOGRAPHY [J].
AOYAGI, N ;
HAYAKAWA, I .
ACTA NEUROCHIRURGICA, 1989, 98 (3-4) :141-147
[2]  
ASAKURA T, 1985, APPL NEUROPHYSIOL, V48, P73
[3]   STEREOTACTIC ASPIRATION OF A BRAIN-STEM HEMATOMA [J].
BEATTY, RM ;
ZERVAS, NT .
NEUROSURGERY, 1983, 13 (02) :204-207
[4]   STEREOTAXIC ANGIOGRAPHY - AN INADEQUATE DATABASE FOR RADIOSURGERY [J].
BOVA, FJ ;
FRIEDMAN, WA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (04) :891-895
[5]   RESULTS OF 1,000 CONSECUTIVE BASAL GANGLIA OPERATIONS FOR PARKINSONISM [J].
COOPER, IS .
ANNALS OF INTERNAL MEDICINE, 1960, 52 (03) :483-499
[6]   THE UNIVERSITY-OF-FLORIDA RADIOSURGERY SYSTEM [J].
FRIEDMAN, WA ;
BOVA, FJ .
SURGICAL NEUROLOGY, 1989, 32 (05) :334-342
[7]   TRANSIENT GLOBAL AMNESIA ASSOCIATED WITH CEREBRAL-ANGIOGRAPHY PERFORMED WITH USE OF IOPAMIDOL [J].
GIANG, DW ;
KIDO, DK .
RADIOLOGY, 1989, 172 (01) :195-196
[8]  
HADLEY MN, 1985, APPL NEUROPHYSIOL, V48, P61
[9]   CEREBRAL ANGIOGRAPHIC RISK IN MILD CEREBROVASCULAR-DISEASE [J].
HANKEY, GJ ;
WARLOW, CP ;
SELLAR, RJ .
STROKE, 1990, 21 (02) :209-222
[10]   INCREASED DETECTION OF INTRACRANIAL METASTASES WITH INTRAVENOUS GD-DTPA [J].
HEALY, ME ;
HESSELINK, JR ;
PRESS, GA ;
MIDDLETON, MS .
RADIOLOGY, 1987, 165 (03) :619-624