HOW WATER EQUIVALENT ARE WATER-EQUIVALENT SOLID MATERIALS FOR OUTPUT CALIBRATION OF PHOTON AND ELECTRON-BEAMS

被引:72
作者
TELLO, VM
TAILOR, RC
HANSON, WF
机构
[1] Radiological Physics Center, Department of Radiation Physics, University of Texas M.D. Anderson Cancer Center, Houston, Texas 77030, Box 547, 1515, Holcombe Boulevard
关键词
WATER EQUIVALENT SOLID; PHANTOMS; ION CHAMBER; ABSORBED DOSE; OUTPUT CALIBRATION; TG-21 CALIBRATION PROTOCOL;
D O I
10.1118/1.597613
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The water equivalency of five ''water-equivalent'' solid phantom materials was evaluated in terms of output calibration and energy characterization over a range of energies for both photon (Co-60 to 24 MV) and electron (6-20 MeV) beams. Evaluations compared absorbed doses calculated from ionization measurements using the same dosimeter in the solid phantom materials and in natural water (H2O). Ionization measurements were taken at various calibration depths. The Radiological Physics Center's standard dosimetry system, a Farmer-type ion chamber in a water phantom, was used. Complying with the TG-21 calibration protocol, absorbed doses were calculated using eight measurement and calculational techniques for photons and five for electrons. Results of repeat measurements taken over a period of 2 1/2 years were reproducible to within a +/-0.3% spread. Results showed that various combinations of measurement techniques and solid phantom materials caused a spread of 3%-4% in the calculation of dose relative to the dose determined from measurements in water for all beam energies on both modalities. An energy dependence of the dose ratios was observed for both photons and electrons.
引用
收藏
页码:1177 / 1189
页数:13
相关论文
共 17 条
[1]  
ALGHAZI MSA, 1993, MED PHYS, V20, P933
[2]  
[Anonymous], 1983, MED PHYS, V10, P741
[3]  
BANK M, 1994, MED PHYS, V21, P963
[4]   CURRENT COLLECTION AND IONIC RECOMBINATION IN SMALL CYLINDRICAL IONIZATION CHAMBERS EXPOSED TO PULSED RADIATION [J].
BOAG, JW ;
CURRANT, J .
BRITISH JOURNAL OF RADIOLOGY, 1980, 53 (629) :471-478
[5]   A SOLID WATER PHANTOM MATERIAL FOR RADIOTHERAPY X-RAY AND GAMMA-RAY BEAM CALIBRATIONS [J].
CONSTANTINOU, C ;
ATTIX, FH ;
PALIWAL, BR .
MEDICAL PHYSICS, 1982, 9 (03) :436-441
[6]   DOSE ERRORS DUE TO CHARGE STORAGE IN ELECTRON-IRRADIATED PLASTIC PHANTOMS [J].
GALBRAITH, DM ;
RAWLINSON, JA ;
MUNRO, P .
MEDICAL PHYSICS, 1984, 11 (02) :197-203
[7]   EFFECTS OF PLASTIC PROTECTIVE CAPS ON THE CALIBRATION OF THERAPY BEAMS IN WATER [J].
HANSON, WF ;
TINOCO, JAD .
MEDICAL PHYSICS, 1985, 12 (02) :243-248
[8]   STOPPING-POWER AND MASS ENERGY-ABSORPTION COEFFICIENT RATIOS FOR SOLID WATER [J].
HO, AK ;
PALIWAL, BR .
MEDICAL PHYSICS, 1986, 13 (03) :403-404
[9]  
OAG JW, 1966, RAD DOSIMETRY, V2, pCH9
[10]  
Prasad S C, 1992, Med Dosim, V17, P205