EVALUATION OF THE PARAMETERS DETERMINING THE PERFORMANCE OF ELECTROCHROMATOGRAPHY IN PACKED CAPILLARY COLUMNS

被引:123
作者
BEHNKE, B [1 ]
GROM, E [1 ]
BAYER, E [1 ]
机构
[1] UNIV TUBINGEN,INST ORGAN CHEM,D-72076 TUBINGEN,GERMANY
关键词
D O I
10.1016/0021-9673(95)00718-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electrochromatography is a variant of reversed-phase liquid chromatography performed in capillary columns whereby transport of the eluent is accomplished by applying an electric field across the length of the column. Column-length restrictions arising from resistance to flow encountered with conventional pumping are absent in electrochromatography, allowing separation in capillaries packed with 1.5-mu m stationary phases up to 50 cm, thus rendering efficiencies of more than 100 000 plates per column. Practical problems, however, have restricted the number of successful applications reported. A number of parameters determining the electrochromatographic performance are investigated: eluent, frits, packed columns and optional supplementary pressure. These factors are investigated separately and then combined stepwise. With thoroughly degassed eluent, frits made of sintered silica gel, and the use of supplementary pressure, stable and reproducible conditions may be readily obtained.
引用
收藏
页码:207 / 213
页数:7
相关论文
共 10 条
[1]   PRESSURIZED GRADIENT ELECTRO-HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BEHNKE, B ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :93-98
[2]   POROUS CERAMIC BED SUPPORTS FOR FUSED-SILICA PACKED CAPILLARY COLUMNS USED IN LIQUID-CHROMATOGRAPHY [J].
CORTES, HJ ;
PFEIFFER, CD ;
RICHTER, BE ;
STEVENS, TS .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (08) :446-448
[3]  
EIMER T, 1994, 6TH INT S HIGH PERF
[4]   MINIATURIZATION IN PRESSURE AND ELECTROENDOSMOTICALLY DRIVEN LIQUID-CHROMATOGRAPHY - SOME THEORETICAL CONSIDERATIONS [J].
KNOX, JH ;
GRANT, IH .
CHROMATOGRAPHIA, 1987, 24 :135-143
[5]   ELECTROCHROMATOGRAPHY IN PACKED TUBES USING 1.5 TO 50 MU-M SILICA-GELS AND ODS BONDED SILICA-GELS [J].
KNOX, JH ;
GRANT, IH .
CHROMATOGRAPHIA, 1991, 32 (7-8) :317-328
[6]   DIRECT CHIRAL SEPARATIONS BY CAPILLARY ELECTROPHORESIS USING CAPILLARIES PACKED WITH AN ALPHA(1)-ACID GLYCOPROTEIN CHIRAL STATIONARY-PHASE [J].
LI, S ;
LLOYD, DK .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3684-3690
[7]   A METHOD FOR THE EXPERIMENTAL-DETERMINATION OF CONTRIBUTIONS TO BAND BROADENING IN ELECTROCHROMATOGRAPHY WITH PACKED CAPILLARIES [J].
REBSCHER, H ;
PYELL, U .
CHROMATOGRAPHIA, 1994, 38 (11-12) :737-743
[8]   THE ANALYSIS OF PHARMACEUTICAL COMPOUNDS USING ELECTROCHROMATOGRAPHY [J].
SMITH, NW ;
EVANS, MB .
CHROMATOGRAPHIA, 1994, 38 (9-10) :649-657
[9]  
TSUDA T, 1992, LC GC, V5, P32
[10]   ELECTROKINETIC REVERSED-PHASE CHROMATOGRAPHY WITH PACKED CAPILLARIES [J].
YAMAMOTO, H ;
BAUMANN, J ;
ERNI, F .
JOURNAL OF CHROMATOGRAPHY, 1992, 593 (1-2) :313-319