DEVELOPMENT OF AN AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE ONLINE PRECONCENTRATION AND DETERMINATION OF TRACE CONCENTRATIONS OF PESTICIDES IN DRINKING-WATER

被引:50
作者
MARVIN, CH
BRINDLE, ID
HALL, CD
CHIBA, M
机构
[1] AGR CANADA,RES STN,VINELAND STN L0R 2E0,ONTARIO,CANADA
[2] BROCK UNIV,DEPT CHEM,ST CATHARINES L2S 3A1,ONTARIO,CANADA
[3] ONTARIO MINIST ENVIRONM,REXDALE M9W 5L1,ONTARIO,CANADA
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 503卷 / 01期
关键词
D O I
10.1016/S0021-9673(01)81498-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated reversed-phase high-performance liquid chromatographic (HPLC) method has been developed for the determination of trace concentrations of propoxur, carbofuran, carbaryl, propham, captan, chloropropham, barban and butylate in drinking water. A 100-ml of sample water is passed through a 3-cm precolumn, packed with 5-μm ODS sorbent, at a flow-rate of 5 ml/min. The HPLC system is then switched to an acetonitrile-water gradient elution program. The analytes, which are concentrated on the procolumn, are eluted and separated on a 25-cm C8 analytical column and determined by measuring the UV absorption at 220 nm. The resolution of analytes is excellent regardless of whether the elution from the precolumn is done unidirectionally or with backflushing. The precolumn can be used repeatedly for at least 30 samples without a significant decrease in efficiency. The total analytical time is 60 min. Tap, distilled, deionized, commercial spring and HPLC-grade waters were analyzed. The lowest detectable concentrations are in the range of 10 × 10-12-460 × 10-12 g/ml for the eight pesticides with 100 ml of sample. © 1990.
引用
收藏
页码:167 / 176
页数:10
相关论文
共 22 条