HUMAN CORONARY AND PERIPHERAL ARTERIES - ONLINE 3-DIMENSIONAL RECONSTRUCTION FROM 2-DIMENSIONAL INTRAVASCULAR US SCANS - WORK IN PROGRESS

被引:23
作者
ROSENFIELD, K
KAUFMAN, J
PIECZEK, AM
LANGEVIN, RE
PALEFSKI, PE
RAZVI, SA
ISNER, JM
机构
[1] TUFTS UNIV,ST ELIZABETHS HOSP,SCH MED,DEPT BIOMED RES,BOSTON,MA 02135
[2] TUFTS UNIV,ST ELIZABETHS HOSP,SCH MED,DEPT SURG,DIV VASC SURG,BOSTON,MA 02135
关键词
ARTERIES; EXTREMITIES; STENOSIS OR OBSTRUCTION; IMAGES; DISPLAY; PROCESSING; INTERVENTIONAL PROCEDURES; ULTRASOUND; (US); TECHNOLOGY;
D O I
10.1148/radiology.184.3.1509074
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To explore the feasibility of computer-based, on-line three-dimensional reconstruction, timed manual withdrawal (pullback) recordings were obtained with two-dimensional intravascular ultrasound (US) in 42 patients who underwent percutaneous revascularization. Three-dimensional processing was performed with commercial software that stacked serially obtained intravascular US scans and created a new set of data points in four steps: interpolation, segmentation, boundary encoding, and surface rendering. In all 42 patients, satisfactory on-line three-dimensional reconstruction was accomplished. In the first three patients, 70-90 seconds was required for three-dimensional processing and display was limited to the sagittal format. In the next six patients, a sagittal display was rendered in 45-60 seconds, and on-line reconstruction in the cylindrical format was achieved within 30 additional seconds. In the last 33 patients, an unlimited number of sagittal views could be produced in 30-40 seconds, the extra time required for cylindrical display was shortened to 15-20 seconds, and a luminal cast display was added to the on-line menu.
引用
收藏
页码:823 / 832
页数:10
相关论文
共 34 条
[1]  
CANTONI C, 1991, SONOVIEW TECHNICAL R
[2]  
CROWLEY RJ, 1990, Patent No. 4951677
[3]   INTRAVASCULAR ULTRASONOGRAPHY VERSUS DIGITAL SUBTRACTION ANGIOGRAPHY - A HUMAN INVIVO COMPARISON OF VESSEL SIZE AND MORPHOLOGY [J].
DAVIDSON, CJ ;
SHEIKH, KH ;
HARRISON, JK ;
HIMMELSTEIN, SI ;
LEITHE, ME ;
KISSLO, KB ;
BASHORE, TM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (03) :633-636
[4]  
DEJESUS S, 1990, Journal of the American College of Cardiology, V15, p106A
[5]   3-DIMENSIONAL IMAGING [J].
FISHMAN, EK ;
MAGID, D ;
NEY, DR ;
CHANEY, EL ;
PIZER, SM ;
ROSENMAN, JG ;
LEVIN, DN ;
VANNIER, MW ;
KUHLMAN, JE ;
ROBERTSON, DD .
RADIOLOGY, 1991, 181 (02) :321-337
[6]  
GURLEY JC, 1990, CIRCULATION, V82, P72
[7]   ARTERIAL-WALL CHARACTERISTICS DETERMINED BY INTRAVASCULAR ULTRASOUND IMAGING - AN INVITRO STUDY [J].
GUSSENHOVEN, EJ ;
ESSED, CE ;
LANCEE, CT ;
MASTIK, F ;
FRIETMAN, P ;
VANEGMOND, FC ;
REIBER, J ;
BOSCH, H ;
VANURK, H ;
ROELANDT, J ;
BOM, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) :947-952
[8]  
HODGSON J, 1988, CIRCULATION S2, V78, P21
[9]   PERCUTANEOUS INTRAVASCULAR-US AS ADJUNCT TO CATHETER-BASED INTERVENTIONS - PRELIMINARY EXPERIENCE IN PATIENTS WITH PERIPHERAL VASCULAR-DISEASE [J].
ISNER, JM ;
ROSENFIELD, K ;
LOSORDO, DW ;
KELLY, S ;
PALEFSKI, P ;
LANGEVIN, RE ;
RAZVI, S ;
PASTORE, JO ;
KOSOWSKY, BD .
RADIOLOGY, 1990, 175 (01) :61-70
[10]   COMBINATION BALLOON-ULTRASOUND IMAGING CATHETER FOR PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY - VALIDATION OF IMAGING, ANALYSIS OF RECOIL, AND IDENTIFICATION OF PLAQUE FRACTURE [J].
ISNER, JM ;
ROSENFIELD, K ;
LOSORDO, DW ;
ROSE, L ;
LANGEVIN, RE ;
RAZVI, S ;
KOSOWSKY, BD .
CIRCULATION, 1991, 84 (02) :739-754