TRANSIENT-BEHAVIOR ANALYSIS OF A MECHANICAL MONOLEAFLET HEART-VALVE PROSTHESIS IN THE CLOSING PHASE

被引:9
作者
CHEON, GJ [1 ]
CHANDRAN, KB [1 ]
机构
[1] UNIV IOWA, DEPT BIOMED ENGN, IOWA CITY, IA 52242 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 1994年 / 116卷 / 04期
关键词
D O I
10.1115/1.2895796
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper, an analysis of the dynamics in the closing phase of the occluder of a mechanical monoleaflet heart valve prosthesis is presented. The dynamic analysis of the fluid in the vicinity of the occluder was based on the control volume approach. The backflow velocity of the fluid was computed by applying the continuity and momentum equations in the unsteady state. By considering the fluid pressure and gravity as external forces acting on the occluder, the moment equilibrium on the occluder was employed to analyze the motion of the occluder during closing and the force of impact between the occluder and the guiding struts. The computed magnitudes of the occluder tip velocities, as well as the backflow of the fluid during the closing phase using this model, were in agreement with previously reported experimental measurements. The maximum impact force between the occluder and guiding struts of 140-280 N was determined to occur during the initial impact for a duration of 35-45 mu s. The results of such model studies may be extended for the analysis of the endurance limit of the valve prostheses as well as to determine the mechanical stresses on the formed elements and the incipience of cavitation bubbles during The closing phase of the valve function.
引用
收藏
页码:452 / 459
页数:8
相关论文
共 22 条
[1]  
BALDWIN JT, 1991, ASAIO T, V37, P348
[2]   DYNAMIC BEHAVIOR ANALYSIS OF MECHANICAL MONOLEAFLET HEART-VALVE PROSTHESES IN THE OPENING PHASE [J].
CHEON, GJ ;
CHANDRAN, KB .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :389-395
[3]   AN INVITRO COMPARATIVE-STUDY OF ST-JUDE MEDICAL AND EDWARDS-DUROMEDICS BILEAFLET VALVES USING LASER ANEMOMETRY [J].
FATEMI, R ;
CHANDRAN, KB .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1989, 111 (04) :298-302
[4]   CAVITATION POTENTIAL OF MECHANICAL HEART-VALVE PROSTHESES [J].
GRAF, T ;
FISCHER, H ;
REUL, H ;
RAU, G .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (03) :169-174
[5]  
GROSS JM, 1991, ASAIO T, V37, P357
[6]   LASER ASSESSMENT OF LEAFLET CLOSING MOTION IN PROSTHETIC HEART-VALVES [J].
GUO, GX ;
XU, CC ;
HWANG, NHC .
JOURNAL OF BIOMEDICAL ENGINEERING, 1990, 12 (06) :477-481
[7]  
GUYTON, 1971, TXB MED PHYSL, P153
[8]  
HAGGAG YAM, 1990, IMECHE J ENG MED, V204, P111
[9]  
LEE CS, 1991, 3RD P US CHIN JAP C, P137
[10]  
LEUER L, 1987, 40TH P ACEMB, P82