EFFECT OF RECYCLE STRUCTURE ON DISTILLATION TOWER TIME CONSTANTS

被引:40
作者
KAPOOR, N [1 ]
MCAVOY, TJ [1 ]
MARLIN, TE [1 ]
机构
[1] EXXON RES & ENGN CO,FLORHAM PK,NJ 07932
关键词
CHEMICAL EQUIPMENT - Control - SEPARATION - Equipment;
D O I
10.1002/aic.690320307
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Recycle of material or energy can change the effective dynamic behavior of a process. Distillation towers are inherently recycle processes. Published tower time constants based on linear analysis have been substantially in error when compared to actual responses for many cases. The reason for this error is shown to be the recycle nature of distillation towers. An improved method of estimating time constants, which can be extended to industrial towers, is presented.
引用
收藏
页码:411 / 418
页数:8
相关论文
共 11 条
[1]   DYNAMICS AND CONTROL OF ACTIVATED-SLUDGE WASTEWATER PROCESS [J].
ATTIR, U ;
DENN, MM .
AICHE JOURNAL, 1978, 24 (04) :693-698
[2]   DYNAMICS OF PLANTS WITH RECYCLE [J].
DENN, MM ;
LAVIE, R .
CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1982, 24 (01) :55-59
[3]  
DENN MM, 1979, CONTROL DYNAMIC SYST, V15, P148
[4]   CONTROL OF HIGH-PURITY DISTILLATION-COLUMNS [J].
FUENTES, C ;
LUYBEN, WL .
INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1983, 22 (03) :361-366
[5]   REDUCTION OF COMPLEX TRANSFER FUNCTION MODELS TO SIMPLE MODELS USING METHOD OF MOMENTS [J].
GIBILARO, LG ;
LEES, FP .
CHEMICAL ENGINEERING SCIENCE, 1969, 24 (01) :85-&
[6]  
GILLILAND ER, 1964, DYNAMIC EFFECTS MAT, P140
[7]  
LUYBEN WL, 1973, PROCESS MODELING SIM, P267
[8]  
MARLIN TE, 1981, 2 P CHEM PROC CONTR
[9]  
RINARD I, 1982, 1982 P ACC
[10]  
THURSTON CW, 1981, HYDROCARB PROCESS, V60, P135