EFFECT OF ANTIARRHYTHMIC DRUG-THERAPY ON THE INCIDENCE OF SHOCKS IN PATIENTS WHO RECEIVE AN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR AFTER A SINGLE EPISODE OF SUSTAINED VENTRICULAR-TACHYCARDIA FIBRILLATION

被引:14
作者
KOU, WH
KIRSH, MM
BOLLING, SF
STIRLING, M
KADISH, AH
DEBUITLEIR, M
CALKINS, H
LEWIS, RRR
MORADY, F
机构
[1] UNIV MICHIGAN HOSP,DEPT INTERNAL MED,DIV CARDIOL,ANN ARBOR,MI 48109
[2] UNIV MICHIGAN HOSP,DEPT SURG,DIV THORAC SURG,ANN ARBOR,MI 48109
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1991年 / 14卷 / 11期
关键词
IMPLANTABLE CARDIOVERTER DEFIBRILLATOR;
D O I
10.1111/j.1540-8159.1991.tb02733.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Seventy-four patients (16 women, 58 men, age 58 +/- 11 years, mean +/- standard deviation) who received an implantable cardioverter defibrillator (ICD) after experiencing a single episode of ventricular tachycardia or ventricular fibrillation were followed to determine if antiarrhythmic drug therapy affects the incidence of ICD discharges. Thirty-three patients (group A) were treated with an antiarrhythmic drug that was either untested or previously demonstrated during electropharmacological testing to be ineffective in suppressing the induction of ventricular tachycardia. Forty-one patients (group B) were not treated with an antiarrhythmic drug. There were no significant differences between the two groups in regards to age, sex, incidence of coronary artery disease, left ventricular function or the type of ICD pulse generator used. During a mean follow-up of 14 months for the entire cohort, 15 patients (46%) in group A and 18 patients (44%) in group B experienced at least one ICD shock. The time to the first appropriate shock (5 +/- 5 months in both groups) and the frequency of ICD shocks (0.3 +/- 0.2/month in group A vs 0.4 +/- 0.5/month in group B) were similar in both groups. The incidence of syncope at the time of ICD discharge was higher in group A than group B patients (31% vs 5%, P < 0.05). In conclusion, antiarrhythmic drugs that are untested or have failed electropharmacological testing do not appear to reduce the probability of ICD discharge over a short-term (mean 14 months) follow-up in patients who have had only one clinical episode of VT/VF and may increase the risk of syncope during ICD discharge. Studies with a larger sample size and longer follow-up period will be needed to confirm these findings.
引用
收藏
页码:1586 / 1592
页数:7
相关论文
共 8 条
[1]   CLINICAL-EXPERIENCE, COMPLICATIONS, AND SURVIVAL IN 70 PATIENTS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR [J].
ECHT, DS ;
ARMSTRONG, K ;
SCHMIDT, P ;
OYER, PE ;
STINSON, EB ;
WINKLE, RA .
CIRCULATION, 1985, 71 (02) :289-296
[2]   ELECTROPHYSIOLOGIC TESTING AND FOLLOW-UP OF PATIENTS WITH ABORTED SUDDEN-DEATH [J].
ELDAR, M ;
SAUVE, MJ ;
SCHEINMAN, MM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (02) :291-298
[3]   MANAGEMENT OF RECURRENT VENTRICULAR-TACHYCARDIA - ECONOMIC-IMPACT OF THERAPEUTIC ALTERNATIVES [J].
FERGUSON, D ;
SAKSENA, S ;
GREENBERG, E ;
CRAELIUS, W .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (04) :531-536
[4]   PREDICTORS OF AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR DISCHARGE FOR LIFE-THREATENING VENTRICULAR ARRHYTHMIAS [J].
KELLY, PA ;
CANNOM, DS ;
GARAN, H ;
FINKELSTEIN, D ;
MCCOMB, JM ;
MIRABAL, GS ;
ILVENTO, JP ;
RUSKIN, JN .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (01) :83-87
[5]  
KIM SG, 1988, NEW ENGL J MED, V315, P356
[6]  
MACHLINSKI FE, 1988, ANN INTERN MED, V104, P481
[7]   TIME TO 1ST SHOCK AND CLINICAL OUTCOME IN PATIENTS RECEIVING AN AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR [J].
MYERBURG, RJ ;
LUCERI, RM ;
THURER, R ;
COOPER, DK ;
ZAMAN, L ;
INTERIAN, A ;
FERNANDEZ, P ;
COX, M ;
GLICKSMAN, F ;
CASTELLANOS, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (02) :508-514
[8]   AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATORS AND SURVIVAL OF PATIENTS WITH LEFT-VENTRICULAR DYSFUNCTION AND MALIGNANT VENTRICULAR ARRHYTHMIAS [J].
TCHOU, PJ ;
KADRI, N ;
ANDERSON, J ;
CACERES, JA ;
JAZAYERI, M ;
AKHTAR, M .
ANNALS OF INTERNAL MEDICINE, 1988, 109 (07) :529-534