HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS

被引:940
作者
BERGMANN, G
GRAICHEN, F
ROHLMANN, A
机构
[1] Oskar-Helene-Heim, Biomechanics-Laboratory, Orthopaedic Hospital, D-1000 Berlin 33
关键词
D O I
10.1016/0021-9290(93)90058-M
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
The resultant hip joint force, its orientation and the moments were measured in two patients during walking and running using telemetering total hip prostheses. One patient underwent bilateral joint replacement and a second patient, additionally suffering from a neuropathic disease and atactic pit patterns, received one instrumented hip implant. The joint loading was observed over the first 30 and 18 months, respectively, following implantation. In the first patient the median peak forces increased with the walking speed from about 280% of the patient's body weight (BW) at 1 km h-1 to approximately 480% BW at 5 km h-1. Jogging and very fast walking both raised the forces to about 550% BW; stumbling on one occasion caused magnitudes of 720% BW. In the second patient median forces at 3 km h-1 were about 410% BW and a force of 870% BW was observed during stumbling. During all types of activities, the direction of the peak force in the frontal plane changed only slightly when the force magnitude was high. Perpendicular to the long femoral axis, the peak force acted predominantly from medial to lateral. The component from ventral to dorsal increased at higher force magnitudes. In one hip in the first patient and in the second patient the direction of large forces approximated the average anteversion of the natural femur. The torsional moments around the stem of the implant were 40.3 N m in the first patient and 24 N m in the second.
引用
收藏
页码:969 / 990
页数:22
相关论文
共 54 条
[1]
BACKMAN S, 1957, ACTA RADIOL S, V146, P29
[2]
INVIVO MEASUREMENT OF HIP-JOINT LOADING .1. PHYSIOTHERAPY [J].
BERGMANN, G ;
ROHLMANN, A ;
GRAICHEN, F .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1989, 127 (06) :672-679
[3]
A COMPARISON OF HIP-JOINT FORCES IN SHEEP, DOG AND MAN [J].
BERGMANN, G ;
SIRAKY, J ;
ROHLMANN, A ;
KOELBEL, R .
JOURNAL OF BIOMECHANICS, 1984, 17 (12) :907-&
[4]
MULTICHANNEL STRAIN-GAUGE TELEMETRY FOR ORTHOPEDIC IMPLANTS [J].
BERGMANN, G ;
GRAICHEN, F ;
SIRAKY, J ;
JENDRZYNSKI, H ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1988, 21 (02) :169-176
[5]
BERGMANN G, 1990, 36TH T ORS NEW ORL, P2
[6]
BERGMANN G, 1981, BIOMECH B, V7, P106
[7]
BERGMANN G, 1991, 37TH P ANN M ORTH RE, P223
[8]
BERGMANN G, 1992, 8TH P M EUR SOC BIOM, P300
[9]
BERGMANN G, 1982, 9TH P WORLD C IMECO, P395
[10]
BERGMANN G, 1979, FUNKTIONELLE DIAGNOS, P214