SOFT-X-RAY SPECTROSCOPY OF METALLOPROTEINS USING FLUORESCENCE DETECTION

被引:34
作者
CRAMER, SP
CHEN, J
GEORGE, SJ
VANELP, J
MOORE, J
TENSCH, O
COLARESI, J
YOCUM, M
MULLINS, OC
CHEN, CT
机构
[1] UNIV CALIF BERKELEY,DIV ENERGY & ENVIRONM,BERKELEY,CA 94720
[2] CANBERRA IND,MERIDEN,CT 06450
[3] SCHLUMBERGER DOLL RES CTR,RIDGEFIELD,CT 06877
[4] AT&T BELL LABS,MURRAY HILL,NJ 07974
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
D O I
10.1016/0168-9002(92)90567-N
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Fluorescence detection methods have been developed for measuring the L2,3 X-ray absorption spectra of first transition series metalloproteins. Samples are prepared as thin films on silicon supports, and mounted on a liquid helium cooled cold finger in a UHV chamber. A windowless Ge array detector discriminates metal L fluorescence from oxygen K(alpha) background. The high resolution, strong sensitivity to chemical environment and amenability to quantitative spectral shape analysis indicate that L-edges of the first transition series metals are a useful probe for bioinorganic studies.
引用
收藏
页码:285 / 289
页数:5
相关论文
共 16 条
[1]   PERFORMANCE OF THE DRAGON SOFT-X-RAY BEAMLINE [J].
CHEN, CT ;
SETTE, F .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1616-1621
[2]   CONCEPT AND DESIGN PROCEDURE FOR CYLINDRICAL ELEMENT MONOCHROMATORS FOR SYNCHROTRON RADIATION [J].
CHEN, CT .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 256 (03) :595-604
[3]   A 13-ELEMENT GE DETECTOR FOR FLUORESCENCE EXAFS [J].
CRAMER, SP ;
TENCH, O ;
YOCUM, M ;
GEORGE, GN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3) :586-591
[4]   NEW FLUORESCENCE DETECTION SYSTEM FOR X-RAY ABSORPTION-SPECTROSCOPY [J].
CRAMER, SP ;
SCOTT, RA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1981, 52 (03) :395-399
[5]  
CRAMER SP, 1988, XRAY ABSORPTION, P257
[6]  
CRAMER SP, 1991, 6TH P INT XAFS C, P640
[7]   ULTRASOFT (C,N,O) X-RAY-FLUORESCENCE DETECTION - PROPORTIONAL-COUNTERS, FOCUSING MULTILAYER MIRRORS, AND SCATTERED-LIGHT SYSTEMATICS [J].
FISCHER, DA ;
COLBERT, J ;
GLAND, JL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1596-1602
[8]   LOCAL-STRUCTURE DETERMINATION AT HIGH DILUTION - INTERNAL OXIDATION OF 75-PPM FE IN CU [J].
HASTINGS, JB ;
EISENBERGER, P ;
LENGELER, B ;
PERLMAN, ML .
PHYSICAL REVIEW LETTERS, 1979, 43 (24) :1807-1810
[9]   FLUORESCENCE DETECTION OF EXAFS - SENSITIVITY ENHANCEMENT FOR DILUTE SPECIES AND THIN-FILMS [J].
JAKLEVIC, J ;
KIRBY, JA ;
KLEIN, MP ;
ROBERTSON, AS ;
BROWN, GS ;
EISENBERGER, P .
SOLID STATE COMMUNICATIONS, 1977, 23 (09) :679-682
[10]  
JENKINS R, 1981, QUANTITATIVE XRAY SP