HIGH-FREQUENCY JET VERSUS CONVENTIONAL VENTILATION IN INFANTS UNDERGOING BLALOCK-TAUSSIG SHUNTS

被引:8
作者
DAVIS, DA [1 ]
RUSSO, PA [1 ]
GREENSPAN, JS [1 ]
SPEZIALI, G [1 ]
SPITZER, A [1 ]
机构
[1] THOMAS JEFFERSON UNIV,DEPT NEONATOL,PHILADELPHIA,PA
关键词
D O I
10.1016/0003-4975(94)90187-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Nine infants undergoing modified Blalock-Taussig shunts were randomized to both high-frequency jet ventilation (HFJV) and conventional ventilation (CV). Vital signs, blood gases, mean airway pressure, lung mechanics, functional residual capacity, and lung movement were compared on both modes of ventilation keeping peak inspiratory and expiratory pressures constant. The mean airway pressure was lower on HFJV than on CV (8.5 versus 10.9 cm H2O). Arterial partial pressure of oxygen was greater on HFJV than on CV (55 versus 46 mm Hg), arterial partial pressure of carbon dioxide was lower on HFJV than on CV (28 versus 37 mm Hg), whereas compliance (0.54 versus 0.56 mL.cm H2O-1.kg(-1)) resistance (110 versus 95 cm H2O/L.s), and functional residual capacity (23 versus 22.5 mL/kg) remained the same. Lung movement and degree of retraction necessary for surgical exposure as evaluated by an independent observer was less with HFJV compared with CV. Compared with CV during the creation of Blalock-Taussig shunts, HFJV provides better gas exchange at lower mean airway pressure with similar lung function, lung volume, and hemodynamics.
引用
收藏
页码:846 / 849
页数:4
相关论文
共 15 条
[1]   EVALUATION OF NEONATAL PULMONARY MECHANICS AND ENERGETICS - A 2-FACTOR LEAST MEAN-SQUARE ANALYSIS [J].
BHUTANI, VK ;
SIVIERI, EM ;
ABBASI, S ;
SHAFFER, TH .
PEDIATRIC PULMONOLOGY, 1988, 4 (03) :150-158
[2]  
BORG U, 1980, ANESTH ANALG, V59, P594
[3]   RANDOMIZED TRIAL OF HIGH-FREQUENCY JET VENTILATION VERSUS CONVENTIONAL VENTILATION IN RESPIRATORY-DISTRESS SYNDROME [J].
CARLO, WA ;
CHATBURN, RL ;
MARTIN, RJ .
JOURNAL OF PEDIATRICS, 1987, 110 (02) :275-282
[4]   HIGH-FREQUENCY JET VENTILATION IN NEONATAL PULMONARY-HYPERTENSION [J].
CARLO, WA ;
BEOGLOS, A ;
CHATBURN, RL ;
WALSH, MC ;
MARTIN, RJ .
AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1989, 143 (02) :233-238
[5]   DECREASE IN AIRWAY PRESSURE DURING HIGH-FREQUENCY JET VENTILATION IN INFANTS WITH RESPIRATORY-DISTRESS SYNDROME [J].
CARLO, WA ;
CHATBURN, RL ;
MARTIN, RJ ;
LOUGH, MD ;
SHIVPURI, CR ;
ANDERSON, JV ;
FANAROFF, AA .
JOURNAL OF PEDIATRICS, 1984, 104 (01) :101-107
[6]  
DICARLO JV, 1992, CRIT CARE MED, V20, P20
[7]   HIGH-FREQUENCY, SMALL-VOLUME VENTILATION DURING THORACIC-SURGERY [J].
GLENSKI, JA ;
CRAWFORD, M ;
REHDER, K .
ANESTHESIOLOGY, 1986, 64 (02) :211-214
[8]   IMMEDIATE IMPROVEMENT IN LUNG-VOLUME AFTER EXOGENOUS SURFACTANT - ALVEOLAR RECRUITMENT VERSUS INCREASED DISTENSION [J].
GOLDSMITH, LS ;
GREENSPAN, JS ;
RUBENSTEIN, SD ;
WOLFSON, MR ;
SHAFFER, TH .
JOURNAL OF PEDIATRICS, 1991, 119 (03) :424-428
[9]  
GREENSPAN J, IN PRESS ANN THORAC
[10]   HIGH-FREQUENCY JET VENTILATION DURING THORACIC SURGICAL-PROCEDURES [J].
HOWLAND, WS ;
CARLON, GC ;
GOLDINER, PL ;
ROONEY, SM ;
CONCEPCION, I ;
BAINS, MS ;
MCCORMACK, PM .
ANESTHESIOLOGY, 1987, 67 (06) :1009-1012