HEMOGLOBIN-BASED OXYGEN CARRIER PRESERVES SUBMAXIMAL EXERCISE CAPACITY IN HUMANS

被引:57
作者
HUGHES, GS
YANCEY, EP
ALBRECHT, R
LOCKER, PK
FRANCOM, SF
ORRINGER, EP
ANTAL, EJ
JACOBS, EE
机构
[1] BIOPURE CORP, BOSTON, MA USA
[2] UNIV N CAROLINA, DEPT MED, CHAPEL HILL, NC USA
关键词
D O I
10.1016/0009-9236(95)90057-8
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objective: The objective of this study was to evaluate the exercise capacity of subjects given an autologous transfusion or a polymerized bovine hemoglobin solution to define the pharmacodynamics and pharmacokinetics of a new hemoglobin-based oxygen carrier (HBOC-201). Methods: Six normal healthy male subjects (ages 25 to 45 years) participated in this randomized, single-blind, two-way crossover study, which took place at Upjohn Research Clinics in Kalamazoo, Mich. A radial artery catheter was inserted in each subject before serial cardiac output and pulmonary function tests and phlebotomy of 15% blood volume (750 ml plus another 250 ml for study laboratories yields 1000 ml, or about 150 gm human hemoglobin), This was followed by isovolemic hemodilution with Ringer's lactate plus an autologous blood transfusion (or HBOC-201) and 1 week later 45 gm bovine hemoglobin of HBOC-201 (or autologous transfusion). Bicycle exercise stress tests to anaerobic threshold (approximate to 65% of predicted maximum aerobic capacity) were done before phlebotomy and at approximate to 45 minutes after the autologous transfusion or HBOC-201 infusion. Results: Subjects had similar exercise and diffusion capacity but lower lactate levels (for up to 24 hours) during HBOC-201 (which paralleled plasma HBOC-201 levels) than during autologous transfusion periods. Oxygen use (uptake) and carbon dioxide production at rest were greater during the HBOC-201 infusion than during the autologous transfusion period. The half-life of HBOC-201 was about 23 hours. Conclusions: Exercise capacity and diffusion capacity were similar after HBOC-201 and autologous transfusion. HBOC-201 resulted in greater oxygen (or uptake) and carbon dioxide production and lower lactate levels compared with autologous transfusion. Under the conditions of the study the physiologic effects of 1 gm bovine hemoglobin of HBOC-201 were similar to 3 gm human hemoglobin from autologous transfusion.
引用
收藏
页码:434 / 443
页数:10
相关论文
共 29 条
[1]  
AYERS LN, 1975, WESTERN J MED, V123, P255
[2]   WORK CAPACITY AFTER BLOOD DONATION [J].
BALKE, B ;
GRILLO, GP ;
KONECCI, EB ;
LUFT, UC .
JOURNAL OF APPLIED PHYSIOLOGY, 1954, 7 (03) :231-238
[3]   NITRIC-OXIDE ATTENUATES CARDIAC MYOCYTE CONTRACTION [J].
BRADY, AJB ;
WARREN, JB ;
POOLEWILSON, PA ;
WILLIAMS, TJ ;
HARDING, SE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 265 (01) :H176-H182
[4]   INTERACTION OF ORGANIC-PHOSPHATES WITH BOVINE HEMOGLOBIN .1. OXYLABILE AND PHOSPHATE-LABILE PROTON BINDING [J].
BREEPOEL, PM ;
KREUZER, F ;
HAZEVOET, M .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1981, 389 (03) :219-225
[6]   ANAEROBIC THRESHOLD ALTERATIONS CAUSED BY ENDURANCE TRAINING IN MIDDLE-AGED MEN [J].
DAVIS, JA ;
FRANK, MH ;
WHIPP, BJ ;
WASSERMAN, K .
JOURNAL OF APPLIED PHYSIOLOGY, 1979, 46 (06) :1039-1046
[7]  
Diem K., 1970, SCI TABLES
[8]   CENTRAL CIRCULATION DURING EXERCISE AFTER VENESECTION AND REINFUSION OF RED BLOOD-CELLS [J].
EKBLOM, B ;
WILSON, G ;
ASTRAND, PO .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (03) :379-383
[9]   RESPONSE TO EXERCISE AFTER BLOOD LOSS AND REINFUSION [J].
EKBLOM, B ;
GOLDBARG, AN ;
GULLBRING, B .
JOURNAL OF APPLIED PHYSIOLOGY, 1972, 33 (02) :175-+
[10]  
ELLSWORTH ML, 1994, NEWS PHYSIOL SCI, V9, P119