REEVALUATION OF THE API-20E IDENTIFICATION SYSTEM VERSUS CONVENTIONAL BIOCHEMICALS FOR IDENTIFICATION OF MEMBERS OF THE FAMILY ENTEROBACTERIACEAE - A NEW LOOK AT AN OLD PRODUCT

被引:42
作者
OHARA, CM
RHODEN, DL
MILLER, JM
机构
关键词
D O I
10.1128/JCM.30.1.123-125.1992
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The API 20E bacterial identification system has been used for 19 years, often as the standard with which other identification systems are compared. Because the accuracy of this system compared with conventional biochemical tests has not been determined in many years, we evaluated the API 20E linear strip by using 291 typical and atypical strains of the family Enterobacteriaceae taken from a culture collection. At 24 h, the API 20E correctly identified by genus and species 229 of 291 (78.7%) of the strains, using Salmonella and Shigella serotyping where indicated. At 48 h, 95.2% were correctly identified by using additional biochemical tests as recommended by the manufacturer. The API 20E misidentified eight (2.7%) strains; these strains were not limited to any particular genus. When 81 of these Enterobacteriaceae strains were arranged into a weighted assortment correlating to the frequency with which they might be found in a clinical laboratory, the API 20E correctly identified 71 (87.7%) at 24 h and 78 (96.3%) at 48 h. This evaluation concluded that the accuracy of the identification of Enterobacteriaceae strains at 24 h (78.7%) may be significantly lower than that of earlier evaluations. However, there is no significant difference in the ability of the API 20E to correctly identify "challenge" type organisms (229 of 291) versus routine hospital isolates (71 of 81) (P > 0.05), but the system is not as accurate as the conventional biochemical method of identification.
引用
收藏
页码:123 / 125
页数:3
相关论文
共 13 条
[2]   USE OF THE AUTOBAC-IDX SYSTEM FOR RAPID IDENTIFICATION OF ENTEROBACTERIACEAE AND NONFERMENTATIVE GRAM-NEGATIVE BACILLI [J].
COSTIGAN, WJ ;
HOLLICK, GE .
JOURNAL OF CLINICAL MICROBIOLOGY, 1984, 19 (02) :301-302
[3]   COMPARISON OF AUTOMATED AND RAPID MANUAL METHODS FOR THE SAME-DAY IDENTIFICATION OF ENTEROBACTERIACEAE [J].
JORGENSEN, JH ;
JOHNSON, JE ;
ALEXANDER, GA ;
PAXSON, R ;
ALDERSON, GL .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1983, 79 (06) :683-687
[4]   EVALUATION OF THE DMS RAPID-E SYSTEM FOR IDENTIFICATION OF CLINICAL ISOLATES OF THE FAMILY ENTEROBACTERIACEAE [J].
KEVILLE, MW ;
DOERN, GV .
JOURNAL OF CLINICAL MICROBIOLOGY, 1984, 20 (05) :1010-1011
[5]  
MCCARTHY LR, 1978, AM J CLIN PATHOL, V69, P161
[6]   COMPARISON OF THE API RAPID-E 4-HOUR SYSTEM WITH THE API-20E OVERNIGHT SYSTEM FOR THE IDENTIFICATION OF ROUTINE CLINICAL ISOLATES OF THE FAMILY ENTEROBACTERIACEAE [J].
OVERMAN, TL ;
PLUMLEY, D ;
OVERMAN, SB ;
GOODMAN, NL .
JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 21 (04) :542-545
[7]   COMPARISON OF THE AUTOSCAN-W/A RAPID BACTERIAL IDENTIFICATION SYSTEM AND THE VITEK AUTOMICROBIC SYSTEM FOR IDENTIFICATION OF GRAM-NEGATIVE BACILLI [J].
PFALLER, MA ;
SAHM, D ;
OHARA, C ;
CIAGLIA, C ;
YU, M ;
YAMANE, N ;
SCHARNWEBER, G ;
RHODEN, D .
JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (07) :1422-1428
[8]  
PFALLER MA, 1986, J CLIN MICROBIOL, V23, P1
[9]   EVALUATION OF PASCO-MIC-ID SYSTEM FOR IDENTIFYING GRAM-NEGATIVE BACILLI [J].
RHODEN, DL ;
SCHABLE, B ;
SMITH, PB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1987, 25 (12) :2363-2366
[10]   AUTOSCAN-4 SYSTEM FOR IDENTIFICATION OF GRAM-NEGATIVE BACILLI [J].
RHODEN, DL ;
SMITH, PB ;
BAKER, CN ;
SCHABLE, B .
JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 22 (06) :915-918